changes
This commit is contained in:
@@ -64,14 +64,15 @@
|
||||
as page 2 — open the Certificate PDF tab to verify.
|
||||
</div>
|
||||
<div class="alert alert-warning" role="alert"
|
||||
invisible="not x_fc_job_id or state != 'draft' or x_fc_thickness_status != 'none' or not partner_id"
|
||||
invisible="state != 'draft' or x_fc_thickness_status != 'none' or not partner_id"
|
||||
style="margin-top:0;">
|
||||
<i class="fa fa-exclamation-triangle" title="Warning"
|
||||
aria-label="Warning"/>
|
||||
<strong> No Fischerscope PDF on the linked QC.</strong>
|
||||
If this customer expects an XRF report with the CoC,
|
||||
have the operator upload the Fischerscope PDF on the
|
||||
QC check before issuing.
|
||||
<strong> No Fischerscope PDF available.</strong>
|
||||
Drop the PDF into the <em>Thickness Report
|
||||
(Fischerscope)</em> tab below, or upload it on the
|
||||
linked QC check, before issuing. Thickness Report
|
||||
certs cannot issue without thickness data.
|
||||
</div>
|
||||
</xpath>
|
||||
|
||||
@@ -80,8 +81,7 @@
|
||||
<!-- Fischerscope file before merging into the cert. -->
|
||||
<xpath expr="//notebook/page[@name='pdf']" position="after">
|
||||
<page string="Thickness Report (Fischerscope)"
|
||||
name="thickness_pdf"
|
||||
invisible="not x_fc_job_id">
|
||||
name="thickness_pdf">
|
||||
<group>
|
||||
<field name="x_fc_thickness_status" widget="badge"
|
||||
readonly="1"
|
||||
@@ -94,25 +94,23 @@
|
||||
widget="many2one_binary"
|
||||
invisible="not x_fc_thickness_pdf_id"/>
|
||||
</group>
|
||||
<separator string="Upload Fischerscope PDF here"/>
|
||||
<group>
|
||||
<field name="x_fc_local_thickness_pdf"
|
||||
filename="x_fc_local_thickness_pdf_filename"
|
||||
readonly="state != 'draft'"/>
|
||||
<field name="x_fc_local_thickness_pdf_filename"
|
||||
invisible="1"/>
|
||||
</group>
|
||||
<div class="text-muted"
|
||||
invisible="x_fc_thickness_status != 'none'">
|
||||
<p>
|
||||
No Fischerscope thickness PDF has been
|
||||
uploaded on the linked QC yet. The CoC will
|
||||
be issued without an appended thickness
|
||||
report. To attach one:
|
||||
uploaded yet. The CoC will be issued without
|
||||
an appended thickness report. Either drop the
|
||||
PDF into the upload field above, OR upload it
|
||||
on the linked QC check and re-open this cert.
|
||||
</p>
|
||||
<ol>
|
||||
<li>Open the linked Plating Job (smart
|
||||
button above)</li>
|
||||
<li>Click into the auto-spawned Quality
|
||||
Check</li>
|
||||
<li>Go to the <em>Thickness Report</em> tab
|
||||
and upload the PDF from the Fischerscope
|
||||
/ XDAL 600 export</li>
|
||||
<li>Pass the QC, then come back here and
|
||||
click Issue</li>
|
||||
</ol>
|
||||
</div>
|
||||
<div class="text-muted"
|
||||
invisible="x_fc_thickness_status != 'pending'">
|
||||
@@ -120,8 +118,8 @@
|
||||
<i class="fa fa-arrow-up" title="Action"
|
||||
aria-label="Action"/>
|
||||
Click <strong>Issue</strong> in the header
|
||||
and the Fischerscope PDF above will be
|
||||
merged into page 2 of the CoC.
|
||||
and the Fischerscope PDF will be merged into
|
||||
page 2 of the CoC.
|
||||
</p>
|
||||
</div>
|
||||
</page>
|
||||
|
||||
Reference in New Issue
Block a user