fix(plating): Manager Desk premature-advance + 6 workflow enforcement gates
**1. Manager Desk: WO no longer jumps to "In Progress" on partial setup**
User-reported bug: when the manager picked a worker, the WO immediately
left the "Unassigned" column even though the bath/tank (or oven, rack,
masking material) wasn't set yet. Worker would see a half-set job in
their queue and couldn't start it.
Fix:
- New compute `mrp.workorder.x_fc_is_release_ready` — True only when
every field button_start would block on is filled in.
- Companion `x_fc_missing_for_release` — comma-list of what's still
missing (used by the UI as a hint chip).
- Manager controller swaps the column filter from
`assigned_user_id == False` to `is_release_ready == False`.
- A WO stays in "Setup Pending" (formerly Unassigned) until BOTH
worker + per-kind equipment are set; only then does it move to
"In Progress".
**Manager Desk template + SCSS**
The user also said "the manager doesn't know what task they're
assigning". WO row now shows:
• Colour-coded WO-kind badge (wet=blue, bake=red, mask=yellow,
rack=grey, inspect=green)
• Required-role icon + name
• Bath / oven / rack / masking-material chips (whatever's set)
• Yellow "Needs: ..." chip listing what's still missing
• Tank picker only shows for wet WOs (no point on a mask WO)
• Open-WO button to drill into the form for advanced edits
**2. Six enforcement gates patched (without breaking the workflow)**
Each gate fires AFTER the manager sets up the WO and the operator
hits Start/Finish — never on create — so the manager → worker → run
flow stays intact.
| # | Gate | Where |
|---|---|---|
| a | SO confirm requires `client_order_ref` (or x_fc_po_number) | sale_order.action_confirm |
| b | Cert issue requires thickness readings (when partner.x_fc_strict_thickness_required) | fp_certificate.action_issue |
| c | Delivery start_route requires assigned_driver_id | fp_delivery.action_start_route |
| d | Bath log create/save requires line_ids (no empty logs) | fp_bath_log create + @api.constrains |
| e | Quality hold: hold_reason + description now `required=True` | fp_quality_hold field schema |
| f | Receiving accept blocks qty mismatch (manager override allowed + logged) | fp_receiving.action_accept |
New partner flag `x_fc_strict_thickness_required` so commercial
customers don't get blocked but aerospace customers do.
**Verified** via `scripts/fp_enforcement_audit.py`: 18/22 ENFORCED
(2 "GAPS" + 2 "ERRs" are all test artifacts — admin bypass + NOT NULL
fires before my custom check; real gates are correct).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -277,6 +277,25 @@ class FpCertificate(models.Model):
|
||||
'(e.g. "AMS 2404", "MIL-C-26074") so the cert '
|
||||
'states which standard the work meets.'
|
||||
) % {'name': rec.name or rec.display_name})
|
||||
# Aerospace / Nadcap customers: actual thickness readings
|
||||
# must be on file BEFORE the cert is issued. The flag lives
|
||||
# on the partner so commercial customers aren't blocked.
|
||||
if (rec.partner_id
|
||||
and 'x_fc_strict_thickness_required' in rec.partner_id._fields
|
||||
and rec.partner_id.x_fc_strict_thickness_required
|
||||
and rec.certificate_type == 'coc'):
|
||||
if not rec.thickness_reading_ids:
|
||||
raise UserError(_(
|
||||
'Cannot issue CoC "%(name)s" — customer "%(cust)s" '
|
||||
'requires actual thickness readings on every CoC '
|
||||
'(Nadcap / aerospace).\n\nLog Fischerscope readings '
|
||||
'against MO %(mo)s via the Tablet Station before '
|
||||
'issuing.'
|
||||
) % {
|
||||
'name': rec.name or rec.display_name,
|
||||
'cust': rec.partner_id.name,
|
||||
'mo': rec.production_id.name if rec.production_id else '?',
|
||||
})
|
||||
rec.state = 'issued'
|
||||
rec.message_post(body=_('Certificate issued.'))
|
||||
|
||||
|
||||
@@ -39,3 +39,12 @@ class ResPartner(models.Model):
|
||||
help='Attach the BoL PDF to the shipping confirmation email. '
|
||||
'Usually only for customers that invoice freight separately.',
|
||||
)
|
||||
x_fc_strict_thickness_required = fields.Boolean(
|
||||
string='Require Thickness Readings on CoC',
|
||||
default=False, tracking=True,
|
||||
help='Aerospace / Nadcap customers expect every CoC to carry '
|
||||
'actual Fischerscope readings (not just "meets spec"). When '
|
||||
'this is on, action_issue() blocks until at least one '
|
||||
'thickness reading has been logged for the MO. Leave off '
|
||||
'for commercial customers.',
|
||||
)
|
||||
|
||||
Reference in New Issue