feat(plating): Sub 8 — split receiving vs inspection + box parity
fp.receiving simplifies to box-count-only (new primary state machine: draft → counted → staged → closed). Legacy inspecting/accepted/discrepancy/resolved states stay in the Selection so existing records load without error but are surfaced behind a manager-only toggle. New box_count_in field + banner that tells the receiver "count boxes only — parts are inspected by the racking crew." New fp.racking.inspection + fp.racking.inspection.line models — one record per MO, auto-created by mrp.production.create() with one line per contributing SO line (qty_expected seeded, qty_found + condition filled in by the racking crew when they open the boxes). State: draft → inspecting → done | discrepancy_flagged (flagged when any line has a non-ok condition or qty variance). Reopen restricted to Plating Manager. WO soft gate: first plating WO button_start raises a UserError when the MO's racking inspection is still Draft or Inspecting. Plating Manager bypasses; later WOs are not gated. fp.delivery gains x_fc_box_count_out. action_mark_delivered calls _fp_check_box_parity which posts a non-blocking chatter warning when boxes out ≠ boxes in (resolved via job_ref → MO.origin → SO → receiving). Warning only — never blocks shipping. Menu entry: Plating → Operations → Racking Inspection. Module version bumps: fusion_plating_receiving → 19.0.3.0.0 fusion_plating_logistics → 19.0.3.0.0 fusion_plating_bridge_mrp → 19.0.12.0.0 (+depends receiving) Smoke on entech: 12/12 assertions pass (one gate test skipped — MO had no WOs to test) including box-count state machine, inspection auto-create, lifecycle, discrepancy flag, and box-parity chatter. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -373,7 +373,7 @@ rewrite code as new requirements surface. Each sub-project has its own design do
|
||||
| 5 | Order-line fields (fp.serial registry, auto job#, coating-scoped thickness dropdown, revision picker) | **Shipped 2026-04-22** | 5, 6, Q2 |
|
||||
| 6 | Contact Profiles & Communication Routing (per-contact flags + per-location routing + global contact; single resolver helper) | **Shipped 2026-04-22** | client transcript A/B/C |
|
||||
| 7 | IoT tuning (per-sensor polling interval + ingest rate-limit; entech seeded with 25 tanks / 50 sensors) | **Shipped 2026-04-22** | client transcript D |
|
||||
| 8 | Receiving / Inspection / QC flow restructure (split receiving vs inspection; racking crew inspects, not receiver) | Pending | client transcript E |
|
||||
| 8 | Receiving / Inspection / QC flow restructure (fp.receiving = box count only; new fp.racking.inspection per MO; WO soft gate; delivery box-parity warning) | **Shipped 2026-04-22** | client transcript E |
|
||||
| ∞ | First-off / last-off QC | Deferred | client transcript F |
|
||||
| ∞ | VEC machine auto-ingest (Word-format thickness report from network-connected XRF; different machine from Fischerscope) | Deferred | client transcript G |
|
||||
|
||||
|
||||
Reference in New Issue