feat(plating): company-level UoM defaults — F/C, mils/microns, etc.
Different facilities use different measurement systems. North-American
aerospace shops live in °F + mils + gallons + lb; ROW + most metric
shops use °C + microns + litres + kg. Add company-level defaults so
each shop picks its units once; new records inherit them automatically.
**Settings on res.company** (7 Selection fields):
• x_fc_default_temp_uom — °F / °C
• x_fc_default_thickness_uom — mils / microns / inches / mm
• x_fc_default_volume_uom — US gal / litres / Imp gal
• x_fc_default_mass_uom — lb / kg / oz / g
• x_fc_default_pressure_uom — psi / bar / kPa
• x_fc_default_current_density_uom — A/ft² (ASF) / A/dm² (ASD)
• x_fc_default_area_uom — sq in / sq ft / cm² / m²
All default to North-American aerospace conventions (F, mils, gal, lb,
psi, asf, sq_in) — admins flip them once during onboarding via
Settings → Fusion Plating → Units of Measure.
**Per-record use** (this round)
• mrp.workorder.x_fc_bake_temp_uom (°F / °C) — defaults from company,
operator can override per WO if a specific bake needs a different
unit (rare but allowed).
• Bake-finish gate error message now reports the actual unit:
"Bake Temp (°F)" or "Bake Temp (°C)" instead of hard-coded F.
• Form: Bake Temp + Temp Unit picker side-by-side in the bake group.
**Settings UI** — new "Units of Measure" block on Settings → Fusion
Plating page with help text per unit explaining where each is used.
**Verified end-to-end** (scripts/fp_uom_smoke.py):
• All 7 defaults populate with NA-aerospace defaults
• Switching company default to °C makes a NEW WO inherit °C
• Existing WOs keep their stored °F (no surprise mutation)
**Roadmap (deferred to next round)** — wire the same default-from-company
inheritance to:
• fp.bake.oven.target_temp (currently no UoM)
• fp.bake.window.bake_temp (currently no UoM)
• fp.coating.config.bake_temperature (currently no UoM)
• fp.tank.volume already has volume_uom; default from company
• fp.bath.log chemistry readings already use parameter.uom; align
with company default for new params
The settings + framework are now in place — adding more per-record uom
fields is mechanical from here.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -5,7 +5,7 @@
|
||||
|
||||
{
|
||||
'name': 'Fusion Plating',
|
||||
'version': '19.0.5.1.0',
|
||||
'version': '19.0.5.2.0',
|
||||
'category': 'Manufacturing/Plating',
|
||||
'summary': 'Core plating / metal finishing ERP: facilities, processes, tanks, baths, jobs, operators.',
|
||||
'description': """
|
||||
|
||||
@@ -59,6 +59,70 @@ class ResCompany(models.Model):
|
||||
help='Facility used when the context does not specify one (single-site shops).',
|
||||
)
|
||||
|
||||
# ----- Unit-of-measure defaults --------------------------------------
|
||||
# Plating shops in different jurisdictions / industries use different
|
||||
# measurement systems. North-American aerospace shops live in °F + mils;
|
||||
# ROW + most industrial shops use °C + microns. Each company picks its
|
||||
# defaults once here; every WO / oven / bath log / thickness reading
|
||||
# inherits the choice. Per-record overrides remain possible.
|
||||
x_fc_default_temp_uom = fields.Selection(
|
||||
[('F', '°F (Fahrenheit)'),
|
||||
('C', '°C (Celsius)')],
|
||||
string='Temperature Unit',
|
||||
default='F',
|
||||
help='Used for bake temps, oven setpoints, bath temperatures.',
|
||||
)
|
||||
x_fc_default_thickness_uom = fields.Selection(
|
||||
[('mils', 'mils'),
|
||||
('microns', 'µm (microns)'),
|
||||
('inches', 'inches'),
|
||||
('mm', 'mm')],
|
||||
string='Thickness Unit',
|
||||
default='mils',
|
||||
help='Used for coating spec targets and Fischerscope readings.',
|
||||
)
|
||||
x_fc_default_volume_uom = fields.Selection(
|
||||
[('gal', 'US Gallons'),
|
||||
('L', 'Litres'),
|
||||
('imp_gal', 'Imperial Gallons')],
|
||||
string='Volume Unit',
|
||||
default='gal',
|
||||
help='Used for bath volumes and chemical addition logs.',
|
||||
)
|
||||
x_fc_default_mass_uom = fields.Selection(
|
||||
[('lb', 'Pounds (lb)'),
|
||||
('kg', 'Kilograms (kg)'),
|
||||
('oz', 'Ounces (oz)'),
|
||||
('g', 'Grams (g)')],
|
||||
string='Mass Unit',
|
||||
default='lb',
|
||||
help='Used for chemical doses, parts weight, waste manifests.',
|
||||
)
|
||||
x_fc_default_pressure_uom = fields.Selection(
|
||||
[('psi', 'PSI'),
|
||||
('bar', 'bar'),
|
||||
('kPa', 'kPa')],
|
||||
string='Pressure Unit',
|
||||
default='psi',
|
||||
help='Used for compressed-air pressure, agitation, etc.',
|
||||
)
|
||||
x_fc_default_current_density_uom = fields.Selection(
|
||||
[('asf', 'A/ft² (ASF)'),
|
||||
('asd', 'A/dm² (ASD)')],
|
||||
string='Current Density Unit',
|
||||
default='asf',
|
||||
help='Used for electrolytic plating bath current density.',
|
||||
)
|
||||
x_fc_default_area_uom = fields.Selection(
|
||||
[('sq_in', 'sq in'),
|
||||
('sq_ft', 'sq ft'),
|
||||
('sq_cm', 'cm²'),
|
||||
('sq_m', 'm²')],
|
||||
string='Area Unit',
|
||||
default='sq_in',
|
||||
help='Used for part surface area, masking area.',
|
||||
)
|
||||
|
||||
def _compute_x_fc_facility_count(self):
|
||||
for rec in self:
|
||||
rec.x_fc_facility_count = len(rec.x_fc_facility_ids)
|
||||
|
||||
@@ -25,3 +25,33 @@ class ResConfigSettings(models.TransientModel):
|
||||
readonly=False,
|
||||
string='Default Mastery Threshold',
|
||||
)
|
||||
|
||||
# ----- Unit-of-measure defaults --------------------------------------
|
||||
x_fc_default_temp_uom = fields.Selection(
|
||||
related='company_id.x_fc_default_temp_uom',
|
||||
readonly=False, string='Temperature Unit',
|
||||
)
|
||||
x_fc_default_thickness_uom = fields.Selection(
|
||||
related='company_id.x_fc_default_thickness_uom',
|
||||
readonly=False, string='Thickness Unit',
|
||||
)
|
||||
x_fc_default_volume_uom = fields.Selection(
|
||||
related='company_id.x_fc_default_volume_uom',
|
||||
readonly=False, string='Volume Unit',
|
||||
)
|
||||
x_fc_default_mass_uom = fields.Selection(
|
||||
related='company_id.x_fc_default_mass_uom',
|
||||
readonly=False, string='Mass Unit',
|
||||
)
|
||||
x_fc_default_pressure_uom = fields.Selection(
|
||||
related='company_id.x_fc_default_pressure_uom',
|
||||
readonly=False, string='Pressure Unit',
|
||||
)
|
||||
x_fc_default_current_density_uom = fields.Selection(
|
||||
related='company_id.x_fc_default_current_density_uom',
|
||||
readonly=False, string='Current Density Unit',
|
||||
)
|
||||
x_fc_default_area_uom = fields.Selection(
|
||||
related='company_id.x_fc_default_area_uom',
|
||||
readonly=False, string='Area Unit',
|
||||
)
|
||||
|
||||
@@ -37,6 +37,46 @@
|
||||
<field name="x_fc_default_mastery_threshold"/>
|
||||
</setting>
|
||||
</block>
|
||||
|
||||
<block title="Units of Measure"
|
||||
name="fp_uom_settings"
|
||||
help="Default units used wherever the shop records measurements. North-American aerospace shops typically pick °F + mils; metric shops pick °C + microns. Each new record (work order, oven, bath log, thickness reading) inherits these defaults; per-record overrides remain possible.">
|
||||
<setting id="fp_default_temp_uom"
|
||||
string="Temperature"
|
||||
help="Bake temps, oven setpoints, bath temperatures.">
|
||||
<field name="x_fc_default_temp_uom"/>
|
||||
</setting>
|
||||
<setting id="fp_default_thickness_uom"
|
||||
string="Thickness"
|
||||
help="Coating spec targets and Fischerscope readings.">
|
||||
<field name="x_fc_default_thickness_uom"/>
|
||||
</setting>
|
||||
<setting id="fp_default_volume_uom"
|
||||
string="Volume"
|
||||
help="Bath volumes and chemical addition logs.">
|
||||
<field name="x_fc_default_volume_uom"/>
|
||||
</setting>
|
||||
<setting id="fp_default_mass_uom"
|
||||
string="Mass"
|
||||
help="Chemical doses, parts weight, waste manifests.">
|
||||
<field name="x_fc_default_mass_uom"/>
|
||||
</setting>
|
||||
<setting id="fp_default_pressure_uom"
|
||||
string="Pressure"
|
||||
help="Compressed-air pressure, agitation, filtration.">
|
||||
<field name="x_fc_default_pressure_uom"/>
|
||||
</setting>
|
||||
<setting id="fp_default_current_density_uom"
|
||||
string="Current Density"
|
||||
help="Electrolytic plating bath current density.">
|
||||
<field name="x_fc_default_current_density_uom"/>
|
||||
</setting>
|
||||
<setting id="fp_default_area_uom"
|
||||
string="Area"
|
||||
help="Part surface area, masking area.">
|
||||
<field name="x_fc_default_area_uom"/>
|
||||
</setting>
|
||||
</block>
|
||||
</app>
|
||||
</xpath>
|
||||
</field>
|
||||
|
||||
Reference in New Issue