folder rename

This commit is contained in:
gsinghpal
2026-04-16 20:53:53 -04:00
parent 3f3ddcbab4
commit 7c7ef06057
634 changed files with 0 additions and 0 deletions

View File

@@ -0,0 +1,70 @@
# -*- coding: utf-8 -*-
# Copyright 2026 Nexa Systems Inc.
# License OPL-1 (Odoo Proprietary License v1.0)
# Part of the Fusion Plating product family.
{
'name': 'Fusion Plating — Electroless Nickel Process Pack',
'version': '19.0.1.0.0',
'category': 'Manufacturing/Plating',
'summary': 'Electroless nickel plating process types (low/mid/high phosphorus, PTFE composite, Ni-B, strike) with bath parameter schemas.',
'description': """
Fusion Plating — Electroless Nickel Process Pack
=================================================
Part of the Fusion Plating product family by Nexa Systems Inc.
This data-only module plugs into the ``fusion_plating`` core and seeds the
process taxonomy and bath chemistry schemas specific to electroless nickel
(EN) plating. No new models, no new views — just records loaded with
``noupdate="1"`` so downstream customizations survive upgrades.
Process types shipped
---------------------
* Electroless Nickel — Low Phosphorus (25% P)
* Electroless Nickel — Mid Phosphorus (69% P)
* Electroless Nickel — High Phosphorus (1013% P)
* Electroless Nickel — PTFE Composite
* Electroless Nickel — Boron Nickel (Ni-B)
* Nickel Strike
Bath parameters shipped
-----------------------
Nickel concentration, sodium hypophosphite, orthophosphite (HPO3),
pH, temperature, metal turnovers (MTO), bath loading, and stabilizer.
Every EN process type shares this same parameter schema; per-bath
target overrides happen on the bath or recipe record in the core.
Hazard awareness
----------------
Every process type carries ``hazard_notes`` that flag:
* WHMIS 2015 Category 1A respiratory sensitizer / suspected carcinogen
status of nickel compounds.
* CEPA Schedule 1 toxic-substance listing for oxidic, sulphidic and
soluble inorganic nickel compounds.
* Reducing-agent / explosion risk from hypophosphite around oxidizers.
* Scald PPE requirement at 8592°C operating temperature.
* Ontario Reg. 833 air-monitoring and NPRI Part 1A reporting triggers.
Install this module after ``fusion_plating``. It depends only on the core
module and ships no security rules or views of its own.
Copyright (c) 2026 Nexa Systems Inc. All rights reserved.
""",
'author': 'Nexa Systems Inc.',
'website': 'https://www.nexasystems.ca',
'maintainer': 'Nexa Systems Inc.',
'support': 'support@nexasystems.ca',
'license': 'OPL-1',
'price': 0.00,
'currency': 'CAD',
'depends': ['fusion_plating'],
'data': [
'data/fp_bath_parameter_data.xml',
'data/fp_process_type_data.xml',
],
'installable': True,
'application': False,
'auto_install': False,
}