chore(plating): de-dash shipped code + intake-neutral customer emails

Replace em-dashes and en-dashes with hyphens across 789 shipped source
files (py/xml/js/scss) so the delivered module reads as human-written;
em-dashes had become a recognizable AI-generated tell. Internal .md dev
notes are excluded. The WO-sticker mojibake strippers keep their dash
search targets (now written — / –). No logic changes: comments
and display strings only; validated with py_compile + lxml parse.

Rewrite the 7 customer notification emails to be intake-neutral
(ship-in / drop-off / pickup) and repair-aware, and fix the Shipped
email documents line (packing slip vs bill of lading; certificate only
when issued). Subjects use a hyphen separator.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
gsinghpal
2026-06-05 00:16:19 -04:00
parent c9eb61ee0c
commit 8c76a16366
789 changed files with 4692 additions and 4692 deletions

View File

@@ -1,4 +1,4 @@
# -*- coding: utf-8 -*-
# Copyright 2026 Nexa Systems Inc.
# License OPL-1 (Odoo Proprietary License v1.0)
# Part of the Fusion Plating product family. Data-only module no Python imports.
# Part of the Fusion Plating product family. Data-only module - no Python imports.

View File

@@ -4,27 +4,27 @@
# Part of the Fusion Plating product family.
{
'name': 'Fusion Plating Aluminum Anodizing Process Pack',
'name': 'Fusion Plating - Aluminum Anodizing Process Pack',
'version': '19.0.1.0.0',
'category': 'Manufacturing/Plating',
'summary': 'Aluminum anodizing process types Type I chromic, Type II sulfuric, Type III hardcoat, plus dye/seal/desmut with bath parameter schemas.',
'summary': 'Aluminum anodizing process types - Type I chromic, Type II sulfuric, Type III hardcoat, plus dye/seal/desmut - with bath parameter schemas.',
'description': """
Fusion Plating Aluminum Anodizing Process Pack
Fusion Plating - Aluminum Anodizing Process Pack
==================================================
Part of the Fusion Plating product family by Nexa Systems Inc.
This data-only module plugs into the ``fusion_plating`` core and seeds the
process taxonomy and bath chemistry schemas specific to aluminum anodizing.
No new models, no new views just records loaded with ``noupdate="1"`` so
No new models, no new views - just records loaded with ``noupdate="1"`` so
downstream customizations survive upgrades.
Process types shipped
---------------------
* Type I Chromic Acid Anodize (MIL-A-8625)
* Type II Sulfuric Anodize, Clear (MIL-A-8625)
* Type II Sulfuric Anodize, Dyed (MIL-A-8625)
* Type III Hardcoat Anodize (MIL-A-8625)
* Type I - Chromic Acid Anodize (MIL-A-8625)
* Type II - Sulfuric Anodize, Clear (MIL-A-8625)
* Type II - Sulfuric Anodize, Dyed (MIL-A-8625)
* Type III - Hardcoat Anodize (MIL-A-8625)
* Dye Immersion
* Hot Water Seal
* Nickel Acetate Seal
@@ -43,9 +43,9 @@ happen on the bath or recipe record in the core.
Hazard awareness
----------------
* Type I (chromic acid) carries the same Cr(VI) carcinogen warnings as
chrome plating NPRI Part 1B reportable, Toronto Ch. 681 Cr(VI) limit
chrome plating - NPRI Part 1B reportable, Toronto Ch. 681 Cr(VI) limit
2 mg/L, mandatory mist suppression and medical surveillance.
* Type II and Type III sulfuric baths are severe splash hazards
* Type II and Type III sulfuric baths are severe splash hazards -
acid-resistant PPE, eyewash within 10 seconds travel, safety shower.
* Type III chilled bath requires mandatory refrigeration and arc flash
PPE at rectifier voltages up to 90V+.

View File

@@ -99,7 +99,7 @@
<field name="target_max">60.0</field>
<field name="warning_tolerance">5.0</field>
<field name="decimals">1</field>
<field name="description">Type I anodize uses chromic acid. Cr(VI) carcinogen prefer Type II.</field>
<field name="description">Type I anodize - uses chromic acid. Cr(VI) carcinogen - prefer Type II.</field>
</record>
<record id="param_an_seal_temp" model="fusion.plating.bath.parameter">

View File

@@ -12,14 +12,14 @@
<odoo noupdate="1">
<record id="ptype_an_type_i" model="fusion.plating.process.type">
<field name="name">Type I Chromic Acid Anodize (MIL-A-8625)</field>
<field name="name">Type I - Chromic Acid Anodize (MIL-A-8625)</field>
<field name="code">AN_TYPE_I</field>
<field name="category_id" ref="fusion_plating.pcat_anodizing"/>
<field name="sequence">10</field>
<field name="color">2</field>
<field name="icon">fa-tint</field>
<field name="description">Chromic acid anodize per MIL-A-8625 Type I. Legacy aerospace finish use only where customer spec mandates.</field>
<field name="hazard_notes">⚠ TYPE I ANODIZE USES CHROMIC ACID HEXAVALENT CHROMIUM CARCINOGEN.
<field name="description">Chromic acid anodize per MIL-A-8625 Type I. Legacy aerospace finish - use only where customer spec mandates.</field>
<field name="hazard_notes">⚠ TYPE I ANODIZE USES CHROMIC ACID - HEXAVALENT CHROMIUM CARCINOGEN.
Use only where customer spec mandates (legacy aerospace). Prefer Type II where possible.
Same Cr(VI) controls as chrome plating apply: mist suppression, air monitoring, medical surveillance.
NPRI Part 1B reportable. Toronto Ch. 681 Cr(VI) limit 2 mg/L, total Cr 4 mg/L.</field>
@@ -27,37 +27,37 @@ NPRI Part 1B reportable. Toronto Ch. 681 Cr(VI) limit 2 mg/L, total Cr 4 mg/L.</
</record>
<record id="ptype_an_type_ii" model="fusion.plating.process.type">
<field name="name">Type II Sulfuric Anodize, Clear (MIL-A-8625)</field>
<field name="name">Type II - Sulfuric Anodize, Clear (MIL-A-8625)</field>
<field name="code">AN_TYPE_II</field>
<field name="category_id" ref="fusion_plating.pcat_anodizing"/>
<field name="sequence">20</field>
<field name="color">4</field>
<field name="icon">fa-tint</field>
<field name="description">Standard sulfuric anodize per MIL-A-8625 Type II, clear (undyed) finish.</field>
<field name="hazard_notes">Sulfuric acid bath severe splash hazard. Acid-resistant PPE mandatory.
<field name="hazard_notes">Sulfuric acid bath - severe splash hazard. Acid-resistant PPE mandatory.
Eyewash within 10 seconds travel. Safety shower required.
Room temperature operation no bath heating needed.
Room temperature operation - no bath heating needed.
Rectifier lockout/tagout required during maintenance.</field>
<field name="parameter_ids" eval="[(6, 0, [ref('param_an_h2so4'), ref('param_an_al'), ref('param_an_temp_ii'), ref('param_an_cd'), ref('param_an_volt')])]"/>
</record>
<record id="ptype_an_type_ii_dye" model="fusion.plating.process.type">
<field name="name">Type II Sulfuric Anodize, Dyed (MIL-A-8625)</field>
<field name="name">Type II - Sulfuric Anodize, Dyed (MIL-A-8625)</field>
<field name="code">AN_TYPE_II_DYE</field>
<field name="category_id" ref="fusion_plating.pcat_anodizing"/>
<field name="sequence">30</field>
<field name="color">6</field>
<field name="icon">fa-tint</field>
<field name="description">Sulfuric anodize per MIL-A-8625 Type II, dyed colour finish. Followed by dye immersion and seal.</field>
<field name="hazard_notes">Sulfuric acid bath severe splash hazard. Acid-resistant PPE mandatory.
<field name="hazard_notes">Sulfuric acid bath - severe splash hazard. Acid-resistant PPE mandatory.
Eyewash within 10 seconds travel. Safety shower required.
Room temperature operation no bath heating needed.
Room temperature operation - no bath heating needed.
Rectifier lockout/tagout required during maintenance.</field>
<field name="parameter_ids" eval="[(6, 0, [ref('param_an_h2so4'), ref('param_an_al'), ref('param_an_temp_ii'), ref('param_an_cd'), ref('param_an_volt')])]"/>
</record>
<record id="ptype_an_type_iii" model="fusion.plating.process.type">
<field name="name">Type III Hardcoat Anodize (MIL-A-8625)</field>
<field name="name">Type III - Hardcoat Anodize (MIL-A-8625)</field>
<field name="code">AN_TYPE_III</field>
<field name="category_id" ref="fusion_plating.pcat_anodizing"/>
<field name="sequence">40</field>
@@ -66,7 +66,7 @@ Rectifier lockout/tagout required during maintenance.</field>
<field name="description">Hardcoat (Type III) anodize per MIL-A-8625. Thick, wear-resistant film on a chilled sulfuric bath.</field>
<field name="hazard_notes">Chilled sulfuric bath (-2 to +5°C). Refrigeration system mandatory.
High voltage (up to 90V+). Arc flash PPE required for rectifier maintenance.
Cold temperature + high current = cooling system critical bath overheat = part burn-through.
Cold temperature + high current = cooling system critical - bath overheat = part burn-through.
Same sulfuric acid hazards as Type II.</field>
<field name="parameter_ids" eval="[(6, 0, [ref('param_an_h2so4'), ref('param_an_al'), ref('param_an_temp_iii'), ref('param_an_cd'), ref('param_an_volt')])]"/>
</record>
@@ -79,7 +79,7 @@ Same sulfuric acid hazards as Type II.</field>
<field name="color">3</field>
<field name="icon">fa-tint</field>
<field name="description">Dye immersion step following Type II anodize. Colour uptake before seal.</field>
<field name="hazard_notes">Acid or heated bath standard PPE, eyewash, ventilation.</field>
<field name="hazard_notes">Acid or heated bath - standard PPE, eyewash, ventilation.</field>
<field name="parameter_ids" eval="[(6, 0, [ref('param_an_dye_conc'), ref('param_an_dye_temp')])]"/>
</record>
@@ -91,7 +91,7 @@ Same sulfuric acid hazards as Type II.</field>
<field name="color">7</field>
<field name="icon">fa-tint</field>
<field name="description">Near-boiling deionized water seal. Hydrates pore walls of the anodic film to close them.</field>
<field name="hazard_notes">Acid or heated bath standard PPE, eyewash, ventilation.</field>
<field name="hazard_notes">Acid or heated bath - standard PPE, eyewash, ventilation.</field>
<field name="parameter_ids" eval="[(6, 0, [ref('param_an_seal_temp'), ref('param_an_seal_ph')])]"/>
</record>
@@ -115,8 +115,8 @@ Ontario Reg. 833 air monitoring for nickel inhalation exposure.</field>
<field name="sequence">80</field>
<field name="color">7</field>
<field name="icon">fa-tint</field>
<field name="description">Dichromate seal. Legacy aerospace process yellow/green tint, chromate corrosion inhibition.</field>
<field name="hazard_notes">Acid or heated bath standard PPE, eyewash, ventilation.</field>
<field name="description">Dichromate seal. Legacy aerospace process - yellow/green tint, chromate corrosion inhibition.</field>
<field name="hazard_notes">Acid or heated bath - standard PPE, eyewash, ventilation.</field>
<field name="parameter_ids" eval="[(6, 0, [ref('param_an_seal_temp'), ref('param_an_seal_ph')])]"/>
</record>
@@ -128,7 +128,7 @@ Ontario Reg. 833 air monitoring for nickel inhalation exposure.</field>
<field name="color">9</field>
<field name="icon">fa-tint</field>
<field name="description">Chemical brightening dip before anodize. Improves specular finish on aluminum substrates.</field>
<field name="hazard_notes">Acid or heated bath standard PPE, eyewash, ventilation.</field>
<field name="hazard_notes">Acid or heated bath - standard PPE, eyewash, ventilation.</field>
<field name="parameter_ids" eval="[(6, 0, [ref('param_an_temp_ii')])]"/>
</record>
@@ -140,7 +140,7 @@ Ontario Reg. 833 air monitoring for nickel inhalation exposure.</field>
<field name="color">9</field>
<field name="icon">fa-tint</field>
<field name="description">Desmut step after caustic etch. Removes smut (alloying elements) before anodize.</field>
<field name="hazard_notes">Acid or heated bath standard PPE, eyewash, ventilation.</field>
<field name="hazard_notes">Acid or heated bath - standard PPE, eyewash, ventilation.</field>
<field name="parameter_ids" eval="[(6, 0, [ref('param_an_temp_ii')])]"/>
</record>