feat(plating): QC gate + mobile checklist + Fischerscope thickness capture
Phase 1 — Backend QC gate (bridge_mrp)
* fp.qc.checklist.template / .line — per-customer checklist definitions
* fusion.plating.quality.check / .line — per-MO instances walked by inspectors
* res.partner.x_fc_requires_qc + x_fc_qc_template_id toggles policy per customer
* mrp.production.button_mark_done blocks close until QC passes (plus optional
thickness-readings + thickness-PDF gates on aerospace templates)
* Auto-spawns the QC on MO confirm from the customer's resolved template
* Fischerscope XDAL 600 PDF parser auto-extracts NiP / Ni% / P% readings on upload
* fp.thickness.reading gains quality_check_id + auto_extracted
Phase 2 — Mobile QC checklist (OWL client action)
* fp_qc_checklist registered under registry.category("actions")
* Reuses shopfloor design tokens (_fp_shopfloor_tokens.scss) — 48 px touch
targets, shadow-based elevation, three-tier contrast, light + dark bundles
* Per-line pass/fail/N/A with numeric value range, mandatory photo, notes
* Fischerscope PDF drop-zone → server-side pdftotext parse
* Sign-off bar with pass / fail / rework actions
Phase 3 — Admin config
* Starter global default + aerospace/Nadcap templates seeded
* Plating → Configuration → QC Checklist Templates (manager-only)
* Plating → Quality → Quality Checks menu
* "Plating Documents" tab on res.partner gains the QC toggle + template picker
* MO form smart button opens the active QC in the mobile checklist
Gap fixes
* Scanner handles FP-QC:<ref> and FP-MO:<name> — launches the checklist
directly on the tablet
* action_spawn_retry clones a fresh QC from a failed one so rework doesn't
need a new MO
All 12 models / routes / gates smoke + E2E tested: 24 assertions pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -107,6 +107,20 @@ export class ShopfloorTablet extends Component {
|
||||
this.state.stationId = result.id;
|
||||
localStorage.setItem("fp_tablet_station_id", String(result.id));
|
||||
this.setMessage(`Station paired: ${result.name}`, "success");
|
||||
} else if (result.action_tag) {
|
||||
// e.g. FP-QC:<ref> or FP-MO:<name> with a pending QC →
|
||||
// launch the mobile checklist directly.
|
||||
this.setMessage(`Launching ${result.pending_qc_name || result.name}…`, "info");
|
||||
this.action.doAction({
|
||||
type: "ir.actions.client",
|
||||
tag: result.action_tag,
|
||||
name: result.pending_qc_name || result.name,
|
||||
params: result.action_params || {},
|
||||
target: "current",
|
||||
});
|
||||
this.state.scannedCode = "";
|
||||
this.state.loading = false;
|
||||
return;
|
||||
} else {
|
||||
this.setMessage(`Scanned ${result.model} — ${result.name || ""}`, "info");
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user