Commit Graph

12 Commits

Author SHA1 Message Date
gsinghpal
152ed86c3a feat(thickness): single Char range field — drop fp.recipe.thickness picker
Per client direction: every order is a thickness RANGE (e.g.
"0.0005-0.0008 mils" or "5-10 mils"), never a single value. The
old picker model (fp.recipe.thickness with a single 'value' Float)
was modelling the wrong concept and overcrowding the order entry
UI. Replaced with one free-text Char field that auto-fills from
last-used or part default.

DELETED entirely:
- fp.recipe.thickness model (file + view + ACL + manifest entry)
- recipe.thickness_option_ids One2many (the picker source)
- "Thickness Options" inline list on the recipe form
- sale.order.line.x_fc_thickness_id (M2O picker)
- account.move.line.x_fc_thickness_id
- fp.delivery.x_fc_thickness_id
- fp.direct.order.line.thickness_id

ADDED:
- sale.order.line.x_fc_thickness_range (Char) — operator types range
- account.move.line.x_fc_thickness_range — for invoice rendering
- fp.delivery.x_fc_thickness_range — for packing slip
- fp.direct.order.line.thickness_range — for the wizard
- fp.part.catalog.x_fc_default_thickness_range — part default

AUTO-FILL CHAIN (sale.order.line + wizard line):
1. Operator already typed → keep
2. Most recent SO line for (this part, this customer) with a
   non-empty thickness_range → copy that
3. part.x_fc_default_thickness_range → copy
4. Blank — operator types

Implemented as both an @api.onchange (interactive) AND a
create() override (programmatic — wizard, sale_mrp bridge,
imports). Same logic in both paths.

WIZARD push-to-defaults: when "Save as Default" toggle is ticked
on a wizard line, persist the line's thickness_range to
part.x_fc_default_thickness_range so future first-customer orders
get a sensible starting point.

REPORTS: customer_line_header.xml + report_fp_wo_sticker.xml now
print the Char range as-typed (no display_name lookup needed).

KEPT (admin documentation only — doesn't affect order entry):
- recipe.thickness_min, thickness_max, thickness_uom on the recipe
  root: documents the recipe's CAPABILITY range. No UI gate; just
  for spec authors to record what the chemistry can produce.

JOB GROUPING: fp.job auto-create groups SO lines by (recipe, part,
spec, thickness, serial). Updated to key on the thickness_range
Char (stripped) instead of the deleted thickness_id integer.

DB cleanup: --update=base ran on the upgrade, dropping the
fp_recipe_thickness table + the four x_fc_thickness_id columns.
Existing data was already nulled in earlier dev work.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-15 08:54:40 -04:00
gsinghpal
7cafab1b9f feat(promote-customer-spec): Phase B — two-picker SO line UX
Spec-side picker (x_fc_customer_spec_id / customer_spec_id) added on:
- sale.order.line (via quality inherit — onchange autofill, create()
  fallback to part default, _prepare_invoice_line carry)
- account.move.line (via quality inherit — invoice rendering)
- fp.part.catalog (via quality inherit — x_fc_default_customer_spec_id)
- fp.direct.order.line (via quality inherit — wizard picker + autofill)
- fp.direct.order.wizard (action_create_order post-creates spec on SO line)

Thickness picker switched to fp.recipe.thickness (replaces coating-scoped):
- sale.order.line.x_fc_thickness_id comodel + domain rewired to recipe
- account.move.line + fp.delivery same
- fp.direct.order.line.thickness_id same

View inherits in quality add Specification picker next to legacy
Primary Treatment column on:
- SO form line tree
- part catalog Default Treatments block
- direct-order wizard line tree + drawer

Wizard files (fp.contract.review.client.email.wizard) pulled from
entech into the repo — they were ahead of the repo. Quality __init__
now imports wizards/.

Legacy x_fc_coating_config_id + treatment_ids remain visible during
transition; Phase E removes them.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-15 01:16:25 -04:00
gsinghpal
0d85063b5e feat(numbering): wire CoC/RCV/DLV/PU into parent-numbered mixin + rename counters
Per-model counter fields on sale.order renamed to x_fc_pn_*_count
to avoid collision with pre-existing compute fields of the same
short name in bridge_mrp / receiving / configurator (silent
compute-override was suppressing the storage). 4 child models
(fp.certificate, fp.receiving, fusion.plating.delivery,
fusion.plating.pickup.request) now derive names as PFX-<parent>
with -NN suffix from the 2nd onward.

fusion.plating.pickup.request gains a sale_order_id field
(optional) so pickups created against an SO get parent-derived
names, while standalone pickups (pre-SO) fall back to PU/YYYY/NNNN.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-12 13:30:37 -04:00
gsinghpal
6b7b44264a changes 2026-05-10 10:25:12 -04:00
gsinghpal
3641b78a66 feat(phase2): Configuration grouped into 7 themed folders
Collapses the flat ~36-entry Configuration list into 7 navigable
folders + Settings (sibling, stays at top of Configuration). Existing
menu IDs unchanged so bookmarks + cross-module data refs still work
— only parent-id moves.

New folder menus (defined in fusion_plating core):
  menu_fp_config_shop_setup       Shop Setup
  menu_fp_config_recipes_steps    Recipes & Steps
  menu_fp_config_materials_tanks  Materials & Tanks
  menu_fp_config_workforce        Workforce
  menu_fp_config_quality_docs     Quality & Documents
  menu_fp_config_pricing_billing  Pricing & Billing
  menu_fp_config_reference_data   Reference Data

Routing per item (sources updated in their owning module):
  Shop Setup       Facilities, Work Centers, Work Centres, Process
                   Categories, Process Types, Bake Ovens, Shopfloor
                   Stations, Vehicles
  Recipes & Steps  Step Library, QC Checklist Templates, Quality Points
  Materials & Tanks  Bath Parameters, Replenishment Rules, Chemicals,
                     Rack Tags, Calibration Equipment, Calibration Events
  Workforce        Operator Certifications, Shop Roles, Training Types,
                   Quality Teams
  Quality & Documents  Customer Specs, Approved Vendor List, Quality
                       Tags, Quality Reasons, Quality Stages, N299
                       Levels, Notification Templates, Notification Log
  Pricing & Billing  Invoice Strategy Defaults, Account Holds
  Reference Data   Value Sets, Value Rotations
  (Settings remains as a sibling at top of Configuration, manager-gated)

Versions bumped: fusion_plating, fusion_plating_quality, _safety,
_shopfloor, _logistics, _culture, _invoicing, _notifications, _nuclear.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-27 22:45:21 -04:00
gsinghpal
66cfe5f97f changes 2026-04-27 09:41:46 -04:00
gsinghpal
f08f328688 changes 2026-04-27 00:11:18 -04:00
gsinghpal
2bfabfe135 feat(plating): Sub 8 — split receiving vs inspection + box parity
fp.receiving simplifies to box-count-only (new primary state
machine: draft → counted → staged → closed). Legacy
inspecting/accepted/discrepancy/resolved states stay in the
Selection so existing records load without error but are surfaced
behind a manager-only toggle. New box_count_in field + banner
that tells the receiver "count boxes only — parts are inspected
by the racking crew."

New fp.racking.inspection + fp.racking.inspection.line models —
one record per MO, auto-created by mrp.production.create() with
one line per contributing SO line (qty_expected seeded, qty_found
+ condition filled in by the racking crew when they open the boxes).
State: draft → inspecting → done | discrepancy_flagged (flagged
when any line has a non-ok condition or qty variance). Reopen
restricted to Plating Manager.

WO soft gate: first plating WO button_start raises a UserError
when the MO's racking inspection is still Draft or Inspecting.
Plating Manager bypasses; later WOs are not gated.

fp.delivery gains x_fc_box_count_out. action_mark_delivered calls
_fp_check_box_parity which posts a non-blocking chatter warning
when boxes out ≠ boxes in (resolved via job_ref → MO.origin → SO
→ receiving). Warning only — never blocks shipping.

Menu entry: Plating → Operations → Racking Inspection.

Module version bumps:
  fusion_plating_receiving  → 19.0.3.0.0
  fusion_plating_logistics  → 19.0.3.0.0
  fusion_plating_bridge_mrp → 19.0.12.0.0 (+depends receiving)

Smoke on entech: 12/12 assertions pass (one gate test skipped —
MO had no WOs to test) including box-count state machine, inspection
auto-create, lifecycle, discrepancy flag, and box-parity chatter.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-23 00:30:36 -04:00
gsinghpal
25c3f6f8d1 feat(plating): Sub 5 — order-line fields (serial, job#, thickness, revision)
Four new fields on every sale.order.line, propagated through to MO,
Delivery, and Invoice for end-to-end traceability:

- fp.serial registry (new model in configurator) with smart-button
  traceability to Sale Order, MO, Delivery, Invoice, Part. M2O on SO
  line; optional; user types a customer serial or clicks Generate
  Serial for a sequence-backed one. Reverse O2M links split across
  configurator (invoice) / bridge_mrp (MO) / logistics (delivery) so
  module load order is respected.
- x_fc_job_number on SO line, auto-sequenced FP-JOB-NNNNN on SO
  confirm. Editable — shops can override for customer/legacy schemes.
- fp.coating.thickness (new child of fp.coating.config) with per-
  config discrete thickness options; x_fc_thickness_id on SO line
  domain-filtered to the line's coating. Auto-clears when coating
  changes.
- x_fc_revision_snapshot Char on SO line, frozen from
  x_fc_part_catalog_id.revision at save. Protects historical SOs from
  later catalog edits. Secondary "Revision" picker on the tree view
  lets users switch between prior revisions of the same part number;
  the Part M2O still surfaces only is_latest_revision rows.

Reports (CoC, packing slip, invoice, BoL) pick up all four via the
Sub 2 customer_line_header macro — one macro edit, four reports.

Smoke on entech: 11 assertions pass including revision snapshot,
generate-serial button, typed-serial create-on-fly, coating→thickness
domain reset, SO confirm auto job#, and MO traceability carry.

Module version bumps:
  fusion_plating_configurator  → 19.0.12.0.0
  fusion_plating_bridge_mrp    → 19.0.11.0.0
  fusion_plating_logistics     → 19.0.2.0.0 (+depends configurator)
  fusion_plating_reports       → 19.0.5.1.0

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-22 23:04:44 -04:00
gsinghpal
11837ed4f5 fix(plating): Manager Desk premature-advance + 6 workflow enforcement gates
**1. Manager Desk: WO no longer jumps to "In Progress" on partial setup**

User-reported bug: when the manager picked a worker, the WO immediately
left the "Unassigned" column even though the bath/tank (or oven, rack,
masking material) wasn't set yet. Worker would see a half-set job in
their queue and couldn't start it.

Fix:
- New compute `mrp.workorder.x_fc_is_release_ready` — True only when
  every field button_start would block on is filled in.
- Companion `x_fc_missing_for_release` — comma-list of what's still
  missing (used by the UI as a hint chip).
- Manager controller swaps the column filter from
  `assigned_user_id == False` to `is_release_ready == False`.
- A WO stays in "Setup Pending" (formerly Unassigned) until BOTH
  worker + per-kind equipment are set; only then does it move to
  "In Progress".

**Manager Desk template + SCSS**

The user also said "the manager doesn't know what task they're
assigning". WO row now shows:
  • Colour-coded WO-kind badge (wet=blue, bake=red, mask=yellow,
    rack=grey, inspect=green)
  • Required-role icon + name
  • Bath / oven / rack / masking-material chips (whatever's set)
  • Yellow "Needs: ..." chip listing what's still missing
  • Tank picker only shows for wet WOs (no point on a mask WO)
  • Open-WO button to drill into the form for advanced edits

**2. Six enforcement gates patched (without breaking the workflow)**

Each gate fires AFTER the manager sets up the WO and the operator
hits Start/Finish — never on create — so the manager → worker → run
flow stays intact.

| # | Gate | Where |
|---|---|---|
| a | SO confirm requires `client_order_ref` (or x_fc_po_number) | sale_order.action_confirm |
| b | Cert issue requires thickness readings (when partner.x_fc_strict_thickness_required) | fp_certificate.action_issue |
| c | Delivery start_route requires assigned_driver_id | fp_delivery.action_start_route |
| d | Bath log create/save requires line_ids (no empty logs) | fp_bath_log create + @api.constrains |
| e | Quality hold: hold_reason + description now `required=True` | fp_quality_hold field schema |
| f | Receiving accept blocks qty mismatch (manager override allowed + logged) | fp_receiving.action_accept |

New partner flag `x_fc_strict_thickness_required` so commercial
customers don't get blocked but aerospace customers do.

**Verified** via `scripts/fp_enforcement_audit.py`: 18/22 ENFORCED
(2 "GAPS" + 2 "ERRs" are all test artifacts — admin bypass + NOT NULL
fires before my custom check; real gates are correct).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 12:54:00 -04:00
gsinghpal
db8b79d22e feat(plating): close 6 compliance gaps from required-fields audit
Following the workforce-E2E + required-fields audit, ship the first 6
high-priority gates so critical workflow + compliance fields can no
longer be left empty by accident.

**1. Invoice payment terms (account.move)**
- create() now auto-inherits `invoice_payment_term_id` from
  partner.property_payment_term_id when missing
- action_post() raises UserError if still missing — accountant must
  pick one before posting (prevents silent "immediate" due-date)

**2. MO facility (mrp.production)**
- action_confirm() auto-derives `x_fc_facility_id` if unset, in order:
  SO override → res.company.x_fc_default_facility_id → first active
  facility — then HARD GATES: raises UserError if still empty.
  Without facility every downstream record (WO, batch, bath log,
  cert) is missing the "where" half of the audit trail.

**3. WO facility (mrp.workorder)**
- Switched `x_fc_facility_id` from related (workcenter only) to a
  proper compute that falls back to production_id.x_fc_facility_id.
  Stub workcenters auto-created from process node names usually have
  no facility — the MO always does (from #2 above).

**4. Thickness reading calibration_std (fp.thickness.reading)**
- `calibration_std_ref` is now `required=True` with sensible default
  ("NiP/Al STD SET SN 100174568"). Nadcap mandates which calibration
  standard the gauge was checked against — without it the cert
  data has no chain back to a metrology record.

**5. Delivery POD gate (fusion.plating.delivery)**
- action_mark_delivered() raises UserError if no `pod_id`. Driver
  must capture POD on the iPad (recipient signature + photos +
  notes) BEFORE marking delivered. Without POD there's no signed
  receipt to back the invoice or defend a delivery dispute.

**6. Certificate spec_reference gate (fp.certificate)**
- action_issue() raises UserError if no `spec_reference`. The cert
  ATTESTS to a spec — leaving it blank produces a piece of paper
  that AS9100 / Nadcap auditors will (rightfully) reject.

**Simulator updated**: scripts/fp_e2e_workforce.py
- Sets net-30 on the test customer + ensures a default facility
- New PHASE 4c: 5 negative tests (one per new gate), each wrapped
  in a SAVEPOINT so SQL constraint violations don't abort the txn
- Driver now creates POD on iPad BEFORE marking delivered

**Final E2E**: 48 PASS / 2 WARN / 0 FAIL out of 50 checks.
The 2 remaining WARNs (bake-window auto-create, first-piece gate)
are expected behaviour — both are coating-driven and the test
coating intentionally doesn't trigger them.

All 7 negative tests now pass:
  ✓ Test 1: WO start without operator → blocked
  ✓ Test 2: WO start on wet WO without bath/tank → blocked
  ✓ Test 3: MO confirm without facility → blocked
  ✓ Test 4: Cert issue without spec_reference → blocked
  ✓ Test 5: Delivery delivered without POD → blocked
  ✓ Test 6: Invoice post without payment terms → blocked
  ✓ Test 7: Thickness reading without cal std → blocked (DB NOT NULL)

Audit script (scripts/fp_required_fields_audit.py) committed too —
it's the diagnostic that surfaced these gaps and can be re-run to
catch new ones.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 10:07:00 -04:00
gsinghpal
7c7ef06057 folder rename 2026-04-16 20:53:53 -04:00