6b7b44264a changes 2026-05-10 10:25:12 -04:00
gsinghpal
c118b7c6b5 feat(plating): close compliance gaps 7-9 — NCR + CAPA + discharge + invoice ref
**7a. NCR close gate** (fusion.plating.ncr.action_close)
Block close unless these are filled in:
  • Description (what happened)
  • Containment Actions (immediate response)
  • Root Cause (why it happened)
  • Disposition (use-as-is / rework / scrap / RTV decision)

A closed NCR without these is useless for AS9100 audits — it's
the entire point of an NCR to document what went wrong, why, and
how we responded. Empty-HTML strings like "<p><br></p>" are
detected as empty too.

**7b. CAPA close gate** (fusion.plating.capa.action_close)
Block close unless:
  • Root Cause Analysis filled in
  • Action Plan filled in
  • Verification (date + verifier) recorded
  • Effectiveness Notes filled when CAPA was marked Not Effective

AS9100 §10.2 / Nadcap require evidence of root-cause analysis,
the corrective/preventive action plan, AND that effectiveness
was verified before the loop is closed.

**8. Invoice ref defensive default** (account.move.create)
Auto-fills `ref` from the source SO's client_order_ref or
x_fc_po_number when the invoice is created with invoice_origin set
but no ref. Already populated on the SO confirm path; this catches
manually-created invoices that would otherwise miss it. Customer
AP teams reject invoices that don't quote their PO# back.

**9. Discharge sample close gate** (fusion.plating.discharge.sample.action_close)
Block close unless:
  • Lab Report # set
  • Results Received Date set
  • At least one parameter reading on file
  • Lab certificate/report attached

Without lab evidence the record fails any environmental compliance
audit — the whole point is to document the test was performed and
what the lab said.

**Simulator** (scripts/fp_e2e_workforce.py)
Adds 4 new negative tests (Test 8-11), all wrapped in savepoints:
  ✓ Test 8 : NCR close without RC/containment/disposition → blocked
  ✓ Test 9 : CAPA close without analysis/plan/verification → blocked
  ✓ Test 10: Discharge sample close without lab evidence → blocked
  ✓ Test 11: Invoice ref auto-fills from SO.client_order_ref → asserted

**Final E2E**: 52 PASS / 2 WARN / 0 FAIL out of 54 checks.
Both remaining WARNs are expected (bake-window auto-create,
first-piece gate — coating-driven, this coating doesn't trigger them).

11 negative tests in total now, every gate fires when triggered.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 10:35:27 -04:00
gsinghpal
db8b79d22e feat(plating): close 6 compliance gaps from required-fields audit
Following the workforce-E2E + required-fields audit, ship the first 6
high-priority gates so critical workflow + compliance fields can no
longer be left empty by accident.

**1. Invoice payment terms (account.move)**
- create() now auto-inherits `invoice_payment_term_id` from
  partner.property_payment_term_id when missing
- action_post() raises UserError if still missing — accountant must
  pick one before posting (prevents silent "immediate" due-date)

**2. MO facility (mrp.production)**
- action_confirm() auto-derives `x_fc_facility_id` if unset, in order:
  SO override → res.company.x_fc_default_facility_id → first active
  facility — then HARD GATES: raises UserError if still empty.
  Without facility every downstream record (WO, batch, bath log,
  cert) is missing the "where" half of the audit trail.

**3. WO facility (mrp.workorder)**
- Switched `x_fc_facility_id` from related (workcenter only) to a
  proper compute that falls back to production_id.x_fc_facility_id.
  Stub workcenters auto-created from process node names usually have
  no facility — the MO always does (from #2 above).

**4. Thickness reading calibration_std (fp.thickness.reading)**
- `calibration_std_ref` is now `required=True` with sensible default
  ("NiP/Al STD SET SN 100174568"). Nadcap mandates which calibration
  standard the gauge was checked against — without it the cert
  data has no chain back to a metrology record.

**5. Delivery POD gate (fusion.plating.delivery)**
- action_mark_delivered() raises UserError if no `pod_id`. Driver
  must capture POD on the iPad (recipient signature + photos +
  notes) BEFORE marking delivered. Without POD there's no signed
  receipt to back the invoice or defend a delivery dispute.

**6. Certificate spec_reference gate (fp.certificate)**
- action_issue() raises UserError if no `spec_reference`. The cert
  ATTESTS to a spec — leaving it blank produces a piece of paper
  that AS9100 / Nadcap auditors will (rightfully) reject.

**Simulator updated**: scripts/fp_e2e_workforce.py
- Sets net-30 on the test customer + ensures a default facility
- New PHASE 4c: 5 negative tests (one per new gate), each wrapped
  in a SAVEPOINT so SQL constraint violations don't abort the txn
- Driver now creates POD on iPad BEFORE marking delivered

**Final E2E**: 48 PASS / 2 WARN / 0 FAIL out of 50 checks.
The 2 remaining WARNs (bake-window auto-create, first-piece gate)
are expected behaviour — both are coating-driven and the test
coating intentionally doesn't trigger them.

All 7 negative tests now pass:
  ✓ Test 1: WO start without operator → blocked
  ✓ Test 2: WO start on wet WO without bath/tank → blocked
  ✓ Test 3: MO confirm without facility → blocked
  ✓ Test 4: Cert issue without spec_reference → blocked
  ✓ Test 5: Delivery delivered without POD → blocked
  ✓ Test 6: Invoice post without payment terms → blocked
  ✓ Test 7: Thickness reading without cal std → blocked (DB NOT NULL)

Audit script (scripts/fp_required_fields_audit.py) committed too —
it's the diagnostic that surfaced these gaps and can be re-run to
catch new ones.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 10:07:00 -04:00
gsinghpal
7c7ef06057 folder rename 2026-04-16 20:53:53 -04:00