Commit Graph

3 Commits

Author SHA1 Message Date
gsinghpal
11837ed4f5 fix(plating): Manager Desk premature-advance + 6 workflow enforcement gates
**1. Manager Desk: WO no longer jumps to "In Progress" on partial setup**

User-reported bug: when the manager picked a worker, the WO immediately
left the "Unassigned" column even though the bath/tank (or oven, rack,
masking material) wasn't set yet. Worker would see a half-set job in
their queue and couldn't start it.

Fix:
- New compute `mrp.workorder.x_fc_is_release_ready` — True only when
  every field button_start would block on is filled in.
- Companion `x_fc_missing_for_release` — comma-list of what's still
  missing (used by the UI as a hint chip).
- Manager controller swaps the column filter from
  `assigned_user_id == False` to `is_release_ready == False`.
- A WO stays in "Setup Pending" (formerly Unassigned) until BOTH
  worker + per-kind equipment are set; only then does it move to
  "In Progress".

**Manager Desk template + SCSS**

The user also said "the manager doesn't know what task they're
assigning". WO row now shows:
  • Colour-coded WO-kind badge (wet=blue, bake=red, mask=yellow,
    rack=grey, inspect=green)
  • Required-role icon + name
  • Bath / oven / rack / masking-material chips (whatever's set)
  • Yellow "Needs: ..." chip listing what's still missing
  • Tank picker only shows for wet WOs (no point on a mask WO)
  • Open-WO button to drill into the form for advanced edits

**2. Six enforcement gates patched (without breaking the workflow)**

Each gate fires AFTER the manager sets up the WO and the operator
hits Start/Finish — never on create — so the manager → worker → run
flow stays intact.

| # | Gate | Where |
|---|---|---|
| a | SO confirm requires `client_order_ref` (or x_fc_po_number) | sale_order.action_confirm |
| b | Cert issue requires thickness readings (when partner.x_fc_strict_thickness_required) | fp_certificate.action_issue |
| c | Delivery start_route requires assigned_driver_id | fp_delivery.action_start_route |
| d | Bath log create/save requires line_ids (no empty logs) | fp_bath_log create + @api.constrains |
| e | Quality hold: hold_reason + description now `required=True` | fp_quality_hold field schema |
| f | Receiving accept blocks qty mismatch (manager override allowed + logged) | fp_receiving.action_accept |

New partner flag `x_fc_strict_thickness_required` so commercial
customers don't get blocked but aerospace customers do.

**Verified** via `scripts/fp_enforcement_audit.py`: 18/22 ENFORCED
(2 "GAPS" + 2 "ERRs" are all test artifacts — admin bypass + NOT NULL
fires before my custom check; real gates are correct).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 12:54:00 -04:00
gsinghpal
db8b79d22e feat(plating): close 6 compliance gaps from required-fields audit
Following the workforce-E2E + required-fields audit, ship the first 6
high-priority gates so critical workflow + compliance fields can no
longer be left empty by accident.

**1. Invoice payment terms (account.move)**
- create() now auto-inherits `invoice_payment_term_id` from
  partner.property_payment_term_id when missing
- action_post() raises UserError if still missing — accountant must
  pick one before posting (prevents silent "immediate" due-date)

**2. MO facility (mrp.production)**
- action_confirm() auto-derives `x_fc_facility_id` if unset, in order:
  SO override → res.company.x_fc_default_facility_id → first active
  facility — then HARD GATES: raises UserError if still empty.
  Without facility every downstream record (WO, batch, bath log,
  cert) is missing the "where" half of the audit trail.

**3. WO facility (mrp.workorder)**
- Switched `x_fc_facility_id` from related (workcenter only) to a
  proper compute that falls back to production_id.x_fc_facility_id.
  Stub workcenters auto-created from process node names usually have
  no facility — the MO always does (from #2 above).

**4. Thickness reading calibration_std (fp.thickness.reading)**
- `calibration_std_ref` is now `required=True` with sensible default
  ("NiP/Al STD SET SN 100174568"). Nadcap mandates which calibration
  standard the gauge was checked against — without it the cert
  data has no chain back to a metrology record.

**5. Delivery POD gate (fusion.plating.delivery)**
- action_mark_delivered() raises UserError if no `pod_id`. Driver
  must capture POD on the iPad (recipient signature + photos +
  notes) BEFORE marking delivered. Without POD there's no signed
  receipt to back the invoice or defend a delivery dispute.

**6. Certificate spec_reference gate (fp.certificate)**
- action_issue() raises UserError if no `spec_reference`. The cert
  ATTESTS to a spec — leaving it blank produces a piece of paper
  that AS9100 / Nadcap auditors will (rightfully) reject.

**Simulator updated**: scripts/fp_e2e_workforce.py
- Sets net-30 on the test customer + ensures a default facility
- New PHASE 4c: 5 negative tests (one per new gate), each wrapped
  in a SAVEPOINT so SQL constraint violations don't abort the txn
- Driver now creates POD on iPad BEFORE marking delivered

**Final E2E**: 48 PASS / 2 WARN / 0 FAIL out of 50 checks.
The 2 remaining WARNs (bake-window auto-create, first-piece gate)
are expected behaviour — both are coating-driven and the test
coating intentionally doesn't trigger them.

All 7 negative tests now pass:
  ✓ Test 1: WO start without operator → blocked
  ✓ Test 2: WO start on wet WO without bath/tank → blocked
  ✓ Test 3: MO confirm without facility → blocked
  ✓ Test 4: Cert issue without spec_reference → blocked
  ✓ Test 5: Delivery delivered without POD → blocked
  ✓ Test 6: Invoice post without payment terms → blocked
  ✓ Test 7: Thickness reading without cal std → blocked (DB NOT NULL)

Audit script (scripts/fp_required_fields_audit.py) committed too —
it's the diagnostic that surfaced these gaps and can be re-run to
catch new ones.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 10:07:00 -04:00
gsinghpal
7c7ef06057 folder rename 2026-04-16 20:53:53 -04:00