# Fusion IoT — Claude Code Instructions ## Purpose Fusion IoT lets Fusion Apps products ingest live sensor readings from hardware mounted on a shop floor — initially tank temperature probes for Fusion Plating, with room to grow into label printers, scales, and any other device Odoo's IoT framework supports. ## Folder contents ``` fusion_iot/ ├── iot_base/ # Repackaged from Odoo S.A. — shared JS utils ├── iot/ # Repackaged from Odoo S.A. — IoT Box mgmt models + UI ├── fusion_plating_iot/ # Our wrapper — sensor→tank mapping + out-of-spec holds ├── pi/ # Pi-side: lightweight systemd poller (no iot_drivers) │ ├── fp_iot_poller.py │ └── fp-iot-poller.service └── scripts/ # One-shot setup + smoke tests ``` ## Live deployments ### Pi #1 — pilot probe (DS18B20, Tank TK-EN-01) | Attribute | Value | |-----------|-------| | Hostname | `fp-iot-01` | | LAN IP | `192.168.10.112` | | **Tailscale IP** | **`100.108.41.97`** | | SSH | `ssh fp-iot-01` (aliased in `~/.ssh/config`, key-based via Tailscale — no password, no sshpass) | | User | `fp` | | Probe serial | `28-000000b276e4` (DS18B20) | | Poller service | `fp-iot-poller.service` — posts to entech every 30s | | Poller config | `/etc/fp-iot/poller.conf` | | Poller logs | `journalctl -u fp-iot-poller -f` | **Tailscale auth**: pre-authed to the `gurpreet6672@` tailnet. Survives reboots (`tailscaled` enabled). ### entech LXC (Odoo server, hosted on our Proxmox — client's ERP runs here) - `iot_base` + `iot` + `fusion_plating_iot` all installed - Ingest endpoint (public): `POST https://erp.enplating.ca/fp/iot/ingest` - Token lives in `ir.config_parameter['fusion_plating_iot.ingest_token']` — rotated via `scripts/fp_iot_setup_live_sensor.py` at setup time; rotate again in Settings → Technical → System Parameters as needed **Why the public URL (not the LAN IP)**: the Pi needs to work at any customer site, not just our office. Using the same URL the customer types into a browser means zero reconfig when the Pi physically moves between sites. `10.200.1.26:8069` would only work when the Pi is on our internal network. **Tailscale on entech**: attempted in LXC 111 but the unprivileged container can't create a tun device and iptables isn't installable (apt state is broken from an unrelated python3-lxml-html-clean conflict). Userspace-networking mode also failed to start cleanly. Skipped — the public HTTPS URL is strictly simpler anyway. If future ops need internal Tailscale reach on entech, either (a) switch to a privileged LXC with tun support, (b) run tailscaled on the host pve-worker5 and reverse-proxy, or (c) fix the apt state first. ## Repackaging notes — `iot_base` + `iot` Both copied as-is from `/Users/gurpreet/Github/RePackaged-Odoo/_dependencies/` (tag Odoo 19). Both are already LGPL-3 upstream — no license flip needed. **Gutted phone-home**: | File | Change | |------|--------| | `iot/models/update.py` | `Publisher_WarrantyContract._get_message` override REMOVED (no more IoT-Box counting-back to Odoo S.A. for enterprise licensing) | | `iot/iot_handlers/lib/load_worldline_library.sh` | DELETED (proprietary Worldline payment lib fetch from download.odoo.com — we don't use Worldline) | **Left intact** (NOT phone-home, don't remove): - `ir_config_parameter.py` — broadcasts `web.base.url` changes to paired IoT boxes via the internal IoT channel (not the internet) - `iot_box.py.version_commit_url` — cosmetic link to odoo/odoo on GitHub - `controllers/main.py` — serves the iot handlers zip to the Pi (this is the point of the module) ## `fusion_plating_iot` — the wrapper ### Models **`fp.tank.sensor`** — maps a physical sensor to a tank + parameter - `device_serial` — hardware unique ID (e.g. DS18B20 1-Wire address) - `iot_device_id` — optional link to `iot.device` if the sensor comes in via Pi proxy - `tank_id` / `bath_id` — where the sensor lives - `parameter_id` — what bath parameter it reports (temperature, pH, etc.) - `alert_min_override` / `alert_max_override` — per-sensor spec override; else inherits from `fusion.plating.bath.parameter.target_min/max` - Cached `last_reading_value` / `last_reading_at` / `last_reading_in_spec` for fast list views **`fp.tank.reading`** — time-series log of every reading - Append-only — never updated/deleted. The compliance record of bath history. - `create()` evaluates each reading against the sensor's alert range - Raises a `fusion.plating.quality.hold` ONCE on the transition from in-spec → out-of-spec (no spam) **`fusion.plating.tank`** — extended with `x_fc_sensor_ids` o2m + `x_fc_has_out_of_spec` bool for the tank form. ### Endpoint — `POST /fp/iot/ingest` For sensors that skip the Pi proxy and POST directly over HTTP. - Auth: `X-FP-IOT-Token` header OR `"token"` key in JSON body, compared to `ir.config_parameter[fusion_plating_iot.ingest_token]` using `hmac.compare_digest` - Seeded token value: `CHANGE-ME-AFTER-INSTALL` — **MUST be rotated immediately after install** via Settings → Technical → System Parameters - Payload: single `{device_serial, value, read_at}` OR batch `{readings: [...]}` - Response: 200 + `{ok: true, accepted: N}`, 401 on auth fail, 404 if device_serial unknown ### Dependencies - `iot` — the server-side Odoo IoT module (in this same folder, needs to be installed first) - `fusion_plating` — for `fusion.plating.tank` + `fusion.plating.bath.parameter` - `fusion_plating_quality` — for `fusion.plating.quality.hold` ### Not yet — Phase B (when Pi hardware arrives) - DS18B20 handler module for `iot_drivers` (the Pi-side proxy) - Systemd service config for running `iot_drivers` on vanilla Raspberry Pi OS - Pi firmware README ## Deployment to entech (LXC 111) ```bash # 1. Sync all three modules rsync -av fusion_iot/iot_base/ pve-worker5:/tmp/iot_base/ rsync -av fusion_iot/iot/ pve-worker5:/tmp/iot/ rsync -av fusion_iot/fusion_plating_iot/ pve-worker5:/tmp/fpi/ ssh pve-worker5 "pct exec 111 -- bash -c ' mv /tmp/iot_base /mnt/extra-addons/custom/ mv /tmp/iot /mnt/extra-addons/custom/ mv /tmp/fpi /mnt/extra-addons/custom/fusion_plating_iot chown -R odoo:odoo /mnt/extra-addons/custom/iot_base /mnt/extra-addons/custom/iot /mnt/extra-addons/custom/fusion_plating_iot '" # 2. Install modules (order matters) ssh pve-worker5 "pct exec 111 -- su - odoo -s /bin/bash -c \ \"/usr/bin/odoo -c /etc/odoo/odoo.conf -d admin -i iot_base,iot,fusion_plating_iot --stop-after-init\"" # 3. Verify # - Settings → Technical → IoT menu appears # - Plating → Operations → Sensors & Readings menu appears # - curl test against /fp/iot/ingest (see README) ``` ## Test commands ```bash # Set a known token odoo shell> env['ir.config_parameter'].set_param('fusion_plating_iot.ingest_token', 'test-secret-123') # Create a sensor manually odoo shell> env['fp.tank.sensor'].create({ 'name': 'Test probe', 'device_serial': '28-test000001', 'device_kind': 'ds18b20', 'tank_id': , 'parameter_id': , }) # POST a reading curl -X POST http://entech:8069/fp/iot/ingest \ -H 'Content-Type: application/json' \ -H 'X-FP-IOT-Token: test-secret-123' \ -d '{"device_serial":"28-test000001","value":87.3}' # → {"ok":true,"accepted":1} # Simulate out-of-spec reading (assuming target_max=90) curl -X POST http://entech:8069/fp/iot/ingest \ -H 'Content-Type: application/json' \ -H 'X-FP-IOT-Token: test-secret-123' \ -d '{"device_serial":"28-test000001","value":95.0}' # → reading created + fusion.plating.quality.hold auto-raised ```