NADCAP-DEMO-001 R. Patel ac7108_10_electroless scheduled

Scheduled electroless nickel slash-sheet audit for Q3 cycle.

NADCAP-DEMO-002 J. Moreno ac7108_12_chrome in_progress

Chrome plating audit currently underway. Day 2 of on-site review.

NADCAP-DEMO-003 S. Whitfield ac7108_base accredited 2 0 closed

Base checklist audit completed with full accreditation. Two merit observations noted for SPC controls and operator training programme.

RISK-DEMO-001 Tank temperature controller failure

Single-point failure risk on Line 2 EN tank — temperature controller is end-of-life with no redundancy.

operational 3 4 identified
RISK-DEMO-002 Single-source nickel sulphamate supply

Only one approved vendor for nickel sulphamate concentrate. Lead time has increased to 12 weeks.

supply_chain 2 5 assessed

Qualify secondary supplier (Atotech). Target completion by Q4.

RISK-DEMO-003 Thickness measurement repeatability

XRF gauge R&R study showed marginal repeatability on thin deposits (< 5 µm).

quality 4 3 treated

Calibrated with new certified reference standards. Operator training refresher completed. Re-running R&R study next week.

RISK-DEMO-004 Prime OEM contract renewal uncertainty

Largest aerospace customer contract expires in 6 months. RFQ response due next quarter.

customer 2 2 monitored

Account review meetings scheduled monthly. Preparing competitive pricing and capacity expansion proposal.

Electroless Nickel Plating Procedure CFG-EN-001 A C

Rev C — Updated rinse-water conductivity limits per customer spec.
Rev B — Added mid-coat thickness checkpoint.
Rev A — Initial baseline release.

Covers AMS 2404 and MIL-C-26074 requirements for medium-phosphorus EN deposits.

Chrome Plating Procedure CFG-CR-001 A B

Rev B — Revised current-density parameters for thin hard chrome.
Rev A — Initial baseline release.

Covers QQ-C-320 and AMS 2460 requirements for hard chrome deposits on aerospace components.

CFT-DEMO-001 NAS1149-C0363A LOT-2026-04-A Certificate of conformance discrepancy flagged during receiving inspection investigation

Supplier certificate references an outdated spec revision. Material quarantined pending metallurgical lab verification. GIDEP report to be filed if counterfeit is confirmed.