Corrosive and toxic. Known carcinogen (Cr VI). Handle with full PPE.
Toxic and sensitizer. Potential carcinogen. Avoid skin contact and inhalation.
Highly corrosive. Causes severe burns. Use acid-resistant PPE.
Corrosive. Causes severe skin burns and eye damage.
Worker slipped on wet floor near rinse station. No injury.
Area cleaned and non-slip mats placed around rinse station.
Minor chemical splash on forearm during tank top-up. First aid administered on-site.
Affected area flushed with water for 15 minutes. First aid kit used.
Worker was not wearing full-length gloves during transfer. PPE policy reminder issued.
Forklift struck chemical storage rack causing minor structural damage. No spill.
Area cordoned off. Structural assessment arranged.
Tight turning radius at dock entrance identified as contributing factor.
Insufficient clearance between rack and dock pillar for forklift turning radius.
Rack relocated 1.5m further from pillar. Floor markings updated.
1. Review of Q1 incidents
2. PPE compliance audit results
3. Ventilation assessment update
All agenda items reviewed. Two corrective actions assigned. Next meeting set for Q2.
1. Review of Q1 corrective actions
2. Summer heat stress protocol
3. Emergency drill scheduling
Personal air sample collected at chrome plating line 1 during normal operations.
Personal air sample collected at nickel plating station during tank maintenance.