Fusion Plating — Aluminum Anodizing Process Pack

Part of the Fusion Plating product family by Nexa Systems Inc.

Data-only module that plugs into the fusion_plating core and seeds the process taxonomy and bath chemistry schemas specific to aluminum anodizing. No new models, no new views — all records load with noupdate="1" so shop customisations survive module upgrades.

Process types shipped

Code Name Category
AN_TYPE_I Type I — Chromic Acid Anodize (MIL-A-8625) Anodizing
AN_TYPE_II Type II — Sulfuric Anodize, Clear (MIL-A-8625) Anodizing
AN_TYPE_II_DYE Type II — Sulfuric Anodize, Dyed (MIL-A-8625) Anodizing
AN_TYPE_III Type III — Hardcoat Anodize (MIL-A-8625) Anodizing
AN_DYE Dye Immersion Post-Treatment
AN_SEAL_HOT Hot Water Seal Post-Treatment
AN_SEAL_NIAC Nickel Acetate Seal Post-Treatment
AN_SEAL_DICHRO Dichromate Seal Post-Treatment
AN_BRIGHT Bright Dip (Pre-Anodize) Preparation
AN_DESMUT Desmut (Post-Etch) Post-Treatment

Bath parameters shipped

Sulfuric acid concentration, dissolved aluminum, bath temperatures (Type II room-temp and Type III chilled), current density, voltage, chromic acid (Type I), seal bath temperature and pH, nickel acetate concentration, and dye concentration/temperature. Per-bath target overrides happen on the bath or recipe records in the core.

Hazard awareness

  • Type I (chromic acid) carries the same Cr(VI) carcinogen warnings as chrome plating. NPRI Part 1B reportable, Toronto Ch. 681 limits apply, mandatory mist suppression and medical surveillance. Prefer Type II wherever customer spec allows.
  • Type II / Type III sulfuric baths are severe splash hazards. Acid-resistant PPE, eyewash within 10 seconds travel, safety shower.
  • Type III chilled bath requires mandatory refrigeration and arc flash PPE at rectifier voltages up to 90 V+.
  • Nickel acetate seal is a WHMIS 2015 Category 1A sensitizer/carcinogen, subject to Ontario Reg. 833 air monitoring.

Installation

Depends on fusion_plating core. Ships no security rules or views of its own.

docker exec odoo-dev-app odoo -d fusion-dev -u fusion_plating_process_anodize --stop-after-init

License

OPL-1 (Odoo Proprietary License v1.0). Copyright (c) 2026 Nexa Systems Inc. All rights reserved.