gsinghpal 2804168d9e feat(plating): per-WO-kind equipment fields + smart auto-fill defaults
User caught two related issues from screenshots of the WO form:

  1. The "Plating Details" tab was meaningless for non-wet WOs —
     bath/tank/dwell/thickness all show as empty for masking, oven
     bake, racking, and inspection steps. A shop with multiple ovens
     had no way to record which oven a bake WO ran in.

  2. When there's only ONE option (single oven, single bath), forcing
     the manager to pick it on every WO is busywork — pin it
     automatically.

**1. WO classification + per-kind equipment**

New `x_fc_wo_kind` (compute, non-stored) Selection field that buckets
each WO into one of: wet / bake / mask / rack / inspect / other.
Classification by priority:
  • bath linked → wet
  • oven linked → bake
  • workcenter's process families wet → wet
  • WO name keyword match (bake/oven/cure → bake;
    mask/de-mask → mask; rack/de-rack → rack;
    inspect/qa/qc/fai → inspect; default → other)

New equipment fields per kind:
  • `x_fc_oven_id` (m2o fp.bake.oven) for bake WOs
  • `x_fc_bake_temp`, `x_fc_bake_duration_hours` — bake parameters
  • Existing bath/tank/rack/thickness reused for wet
  • Existing rack reused for rack WOs

**2. Required-fields gate extended**

button_start now also requires `x_fc_oven_id` for bake WOs (alongside
the existing operator + bath/tank rules). Without an oven the
chart-recorder trail can't be tied back to the WO for compliance.

**3. View reorganized**

Process Details tab now shows only the equipment groups that apply
to this WO's kind (using `invisible="x_fc_wo_kind != 'bake'"` etc.).
Mask + Inspection + Other show informational alerts instead of
empty form fields. WO header shows a colour-coded kind badge.

**4. Smart auto-fill defaults**

New `_fp_autofill_default_equipment()` method on mrp.workorder. When
the facility has exactly ONE active option, it pre-pins:
  • Bath → if facility has 1 active bath
  • Tank → if the chosen bath has 1 active tank
  • Oven → if facility has 1 active oven

Hooked from:
  • `@api.onchange('workcenter_id', 'x_fc_facility_id', 'x_fc_bath_id')`
    → fills as user edits in the form
  • Recipe → WO generation `_generate_workorders_from_recipe()`
    → fills at creation time so single-line shops never see an
    empty bath/oven field

None of this overwrites an already-set value. Multi-line shops still
get a blank field to choose from.

**Simulator updates** (scripts/fp_e2e_workforce.py)
  • Creates an oven if none exists
  • Pins per-kind equipment in Hannah's planning step
  • New PASS check: bake-WO auto-pinned to default oven
  • New negative test 2b: bake WO with oven stripped → blocked

**Final E2E**: 54 PASS / 2 WARN / 0 FAIL out of 56 checks.
12 negative tests passing — all gates fire when triggered:
  Tests 1-2 + 2b: WO start (operator + bath/tank + oven)
  Tests 3-7: MO facility, cert spec, delivery POD, invoice
             payment terms, thickness cal std
  Tests 8-11: NCR close, CAPA close, discharge close, invoice ref

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 10:47:01 -04:00
..
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00
2026-04-16 20:53:53 -04:00