Phase A of the IoT initiative — gets the server-side infrastructure
in place before the Raspberry Pi hardware arrives, so the iot admin
UI + /fp/iot/ingest endpoint are ready to accept the first real
temperature reading as soon as the Pi is wired up.
New top-level folder: fusion_iot/
1. **iot_base/** — Odoo S.A. iot_base module, copied from
RePackaged-Odoo verbatim. LGPL-3 upstream, no changes needed.
2. **iot/** — Odoo S.A. iot module, repackaged:
- `models/update.py` neutralised (removed the publisher_warranty
IoT-Box-counting report that phones home to odoo.com for
enterprise licence enforcement)
- `iot_handlers/lib/load_worldline_library.sh` deleted (proprietary
Worldline payment lib fetch from download.odoo.com, not needed)
- `wizard/add_iot_box.py._connect_iot_box_with_pairing_code` —
upstream called odoo.com's iot-proxy to resolve pairing codes;
replaced with a no-op. Pi-side iot_drivers proxy registers
directly with this Odoo server instead.
- Manifest rebranded with an explicit changelog preamble.
3. **fusion_plating_iot/** — new plating-specific wrapper:
- `fp.tank.sensor` — maps an iot.device (or a direct-HTTP-ingest
sensor) to a fusion.plating.tank + fusion.plating.bath.parameter.
Supports DS18B20, PT100/1000, pH, conductivity, level. Per-sensor
alert_min/max overrides.
- `fp.tank.reading` — append-only time-series. On create, evaluates
against sensor's alert range. On in-spec → out-of-spec TRANSITION,
auto-raises a fusion.plating.quality.hold (once per excursion,
no spam during sustained out-of-spec).
- `POST /fp/iot/ingest` — shared-secret HTTP endpoint for sensors
bypassing the Pi proxy. Token via X-FP-IOT-Token header OR body.
Accepts single-reading or batch payloads.
- Menu under Plating → Operations → Sensors & Readings.
- Tank form inherits get a Sensors tab inline.
Deployed to entech. Verified end-to-end:
- Install: iot_base + iot + fusion_plating_iot all 'installed'
- Smoke test: in-spec → out-of-spec → hold raised (HOLD-0010);
continued excursion → NO duplicate hold; back-in-spec → NEW
excursion → NEW hold (HOLD-0011) ✓
- HTTP endpoint: correct token → 200 accepted; wrong token → 401;
unknown device_serial → 404; batch payload → 200 accepted=N ✓
Phase B (when Raspberry Pi hardware arrives): DS18B20 iot_handler
driver for the Pi-side iot_drivers proxy + systemd service on
vanilla Raspberry Pi OS + first live reading from physical probe.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
73 lines
2.2 KiB
Python
73 lines
2.2 KiB
Python
from gatt import DeviceManager as Gatt_DeviceManager
|
|
import dbus
|
|
from gi.repository import GLib
|
|
import logging
|
|
from threading import Thread
|
|
|
|
from odoo.addons.iot_drivers.interface import Interface
|
|
|
|
bt_devices = {}
|
|
|
|
_logger = logging.getLogger(__name__)
|
|
|
|
class GattBtManager(Gatt_DeviceManager):
|
|
def device_discovered(self, device):
|
|
identifier = "bt_%s" % device.mac_address
|
|
if identifier not in bt_devices:
|
|
device.manager = self
|
|
bt_devices[identifier] = device
|
|
|
|
def run(self):
|
|
""" Override gatt.DeviceManager.run() method
|
|
to avoid calling GObject.MainLoop() deprecated method inside it.
|
|
MainLoop.run() will 'infinite loop' until MainLoop.quit()
|
|
method is called which we never do, so we don't need to reimplement
|
|
the rest of the MainLoop.run() method """
|
|
|
|
if self._main_loop:
|
|
return
|
|
|
|
self._interface_added_signal = self._bus.add_signal_receiver(
|
|
self._interfaces_added,
|
|
dbus_interface='org.freedesktop.DBus.ObjectManager',
|
|
signal_name='InterfacesAdded')
|
|
|
|
self._properties_changed_signal = self._bus.add_signal_receiver(
|
|
self._properties_changed,
|
|
dbus_interface=dbus.PROPERTIES_IFACE,
|
|
signal_name='PropertiesChanged',
|
|
arg0='org.bluez.Device1',
|
|
path_keyword='path')
|
|
|
|
def disconnect_signals():
|
|
for device in self._devices.values():
|
|
device.invalidate()
|
|
self._properties_changed_signal.remove()
|
|
self._interface_added_signal.remove()
|
|
|
|
self._main_loop = GLib.MainLoop()
|
|
try:
|
|
self._main_loop.run()
|
|
disconnect_signals()
|
|
except Exception:
|
|
disconnect_signals()
|
|
raise
|
|
|
|
class BtManager(Thread):
|
|
def run(self):
|
|
dm = GattBtManager(adapter_name='hci0')
|
|
for device in [device_con for device_con in dm.devices() if device_con.is_connected()]:
|
|
device.disconnect()
|
|
dm.start_discovery()
|
|
dm.run()
|
|
|
|
class BTInterface(Interface):
|
|
connection_type = 'bluetooth'
|
|
|
|
def get_devices(self):
|
|
return bt_devices.copy()
|
|
|
|
bm = BtManager()
|
|
bm.daemon = True
|
|
bm.start()
|