Operators now drop a .docx or .pdf Fischerscope XDAL 600 export
on the cert form's Thickness Report tab. The wizard parses the
readings, calibration std, operator + date metadata, and the
embedded microscope image, then shows them for review before
recording on fp.certificate.
Operator Wizard Certificate
─────────────────────────────────────────────────────────────
Click "Upload Parse .docx / - thickness_reading_ids
Thickness .pdf → written (3 rows)
Report" Show 3 readings - x_fc_local_thickness
Pick file + metadata _pdf attached (original
Click Parse Click Save file)
- microscope image as
ir.attachment on cert
- chatter post
─────────────────────────────────────────────────────────────
When parse can't find readings (unrecognised format), wizard falls
through to manual state — operator can still save, file lands on
the cert as-is for the existing CoC page-2 merge logic.
Closes the gap in the S19 enforcement: x_fc_send_thickness_report
customers blocked at action_issue until the file is on file. Now
they have a parseable upload UX, not just a bare Binary field.
Architecture
- fischerscope_parser.py: pure-Python lib, branches on extension,
python-docx + PyPDF2 already on entech (no new deps). Regex
extraction returns {readings, metadata, image, errors}.
- fp.thickness.upload.wizard: TransientModel with upload/review/
manual states. Lazy-imports parser at action_parse time to dodge
Python 3.11 partial-init relative-import error.
- 27 tests (TestFischerscopeParser 9 + TestThicknessUploadWizard 8
+ the rehoused TestActionIssueGates 10) — all green on entech.
Same metadata copies onto every reading row, microscope image
attaches once at cert level (decisions 2026-05-19).
Drive-by fixes uncovered while running tests on entech:
- fp.certificate.action_issue: guard rec.company_id access with
field-existence check. Lazy-fill-signer branch crashed when
certified_by_id was unset on certs that don't carry a company_id
field. Pre-existing bug that never fired in production because
jobs auto-fill certified_by_id before reaching this branch.
- test_action_issue_gates: set x_fc_send_thickness_report=False on
the test partner. Field defaults to True so every cert in this
class hit the thickness gate; tests were never able to verify
the other gates in isolation.
- Tests directory missing test_action_issue_gates.py on entech.
Synced; turns out the 2026-05-18 "changes" commit added the file
locally but the deploy script never copied tests/.
Module: fusion_plating_certificates 19.0.6.4.0 → 19.0.7.0.0
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
47 lines
1.5 KiB
Python
47 lines
1.5 KiB
Python
# -*- coding: utf-8 -*-
|
|
# Copyright 2026 Nexa Systems Inc.
|
|
# License OPL-1 (Odoo Proprietary License v1.0)
|
|
# Part of the Fusion Plating product family.
|
|
|
|
{
|
|
'name': 'Fusion Plating — Certificates',
|
|
'version': '19.0.7.0.0',
|
|
'category': 'Manufacturing/Plating',
|
|
'summary': 'Certificate registry for CoC, thickness reports, and quality documents.',
|
|
'description': """
|
|
Fusion Plating — Certificates
|
|
===============================
|
|
|
|
Unified certificate registry tracking all quality documents issued to customers.
|
|
Includes Fischerscope thickness measurement data capture.
|
|
""",
|
|
'author': 'Nexa Systems Inc.',
|
|
'website': 'https://www.nexasystems.ca',
|
|
'maintainer': 'Nexa Systems Inc.',
|
|
'support': 'support@nexasystems.ca',
|
|
'license': 'OPL-1',
|
|
'price': 0.00,
|
|
'currency': 'CAD',
|
|
'depends': [
|
|
'fusion_plating',
|
|
'fusion_plating_portal',
|
|
'fusion_plating_batch',
|
|
'fusion_plating_configurator',
|
|
'fusion_plating_logistics',
|
|
'sale_management',
|
|
],
|
|
'data': [
|
|
'security/ir.model.access.csv',
|
|
'data/fp_certificate_sequence_data.xml',
|
|
'views/res_config_settings_views.xml',
|
|
'views/fp_certificate_views.xml',
|
|
'views/res_partner_views.xml',
|
|
'views/fp_certificates_menu.xml',
|
|
'wizards/fp_cert_void_wizard_views.xml',
|
|
'wizards/fp_thickness_upload_wizard_views.xml',
|
|
],
|
|
'installable': True,
|
|
'application': False,
|
|
'auto_install': False,
|
|
}
|