gsinghpal cd0c08f348 fix(plating): parse Fischerscope .doc/.docx/RTF dropped on the cert form
The cert form's x_fc_local_thickness_pdf field only stored the upload; only
the Issue Certs wizard parsed it. Add create/write hooks on the jobs-side
fp.certificate that, when a NON-PDF is written to that field, run the wizard's
parser: readings -> thickness_reading_ids, header metadata -> x_fc_thickness_*,
microscope image (RTF) -> x_fc_thickness_image_id, then relocate the source to
x_fc_local_thickness_evidence_id and clear the PDF field (mirrors the wizard's
non-PDF end state). Real PDFs pass through untouched for the page-2 merge.
Re-entry guarded via the fp_skip_thickness_parse context flag. Bump jobs
19.0.11.3.0.

Deployed + verified on entech: CoC-30065 (.doc) back-filled to 3 readings +
metadata (operator BK) + extracted microscope image, renders inline (242KB);
PDF cert CoC-30040-02 correctly left untouched.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-05-28 23:01:02 -04:00

283 lines
12 KiB
Python

# -*- coding: utf-8 -*-
# Copyright 2026 Nexa Systems Inc.
# License OPL-1 (Odoo Proprietary License v1.0)
#
# Phase 3 — parallel job link on fp.certificate.
# Coexists with bridge_mrp's production_id link.
#
# v19.0.6.20.0 — surface the Fischerscope PDF on the cert form so
# operators can SEE that the thickness report will be (or has been)
# merged into the CoC. The merge logic itself lives in
# fusion_plating_certificates/models/fp_certificate.py — this file
# only adds the human-readable indicators.
from odoo import api, fields, models
class FpCertificate(models.Model):
_inherit = 'fp.certificate'
x_fc_job_id = fields.Many2one(
'fp.job',
string='Work Order',
index=True,
help="Native fp.job link. Coexists with bridge_mrp's production_id.",
)
# ---- Fischerscope thickness-PDF visibility (S19) ---------------------
# These three fields are computed from the linked job's QC checks so
# the cert form can show the operator BEFORE issuing whether a
# Fischerscope report is on file and will be appended as page 2.
x_fc_thickness_qc_id = fields.Many2one(
'fusion.plating.quality.check',
string='Linked QC (Thickness)',
compute='_compute_fischer_visibility',
help='Quality check on the linked plating job that has a '
'Fischerscope / XDAL 600 thickness PDF uploaded. Used to '
'merge that PDF into the CoC on Issue.',
)
x_fc_thickness_pdf_id = fields.Many2one(
'ir.attachment',
string='Fischerscope PDF',
compute='_compute_fischer_visibility',
help='Thickness report PDF that will be appended as page 2 of '
'the CoC when the certificate is issued.',
)
x_fc_thickness_status = fields.Selection(
[
('none', 'No PDF Uploaded'),
('pending', 'Will Append on Issue'),
('merged', 'Merged into CoC'),
],
string='Thickness Report',
compute='_compute_fischer_visibility',
help='none = QC has no Fischerscope upload · '
'pending = will be appended when Issue is clicked · '
'merged = already in the issued CoC PDF',
)
@api.depends('x_fc_job_id', 'state', 'message_ids', 'attachment_id',
'x_fc_local_thickness_pdf')
def _compute_fischer_visibility(self):
QC = self.env.get('fusion.plating.quality.check')
empty_qc = self.env['fusion.plating.quality.check'] if QC is not None else None
empty_att = self.env['ir.attachment']
for rec in self:
qc = empty_qc
pdf = empty_att
status = 'none'
# Cert-local upload wins over QC-side PDF (matches the
# merge resolution order in fp_certificate.py).
if rec.x_fc_local_thickness_pdf:
if rec.state == 'issued' and rec.attachment_id:
status = 'merged'
else:
status = 'pending'
elif QC is not None and rec.x_fc_job_id:
# Same lookup the merge method uses — passed-first,
# then any QC with a PDF.
qc = QC.sudo().search([
('job_id', '=', rec.x_fc_job_id.id),
('state', '=', 'passed'),
('thickness_report_pdf_id', '!=', False),
], order='completed_at desc', limit=1)
if not qc:
qc = QC.sudo().search([
('job_id', '=', rec.x_fc_job_id.id),
('thickness_report_pdf_id', '!=', False),
], order='create_date desc', limit=1)
if qc and qc.thickness_report_pdf_id:
pdf = qc.thickness_report_pdf_id
if rec.state == 'issued' and rec.attachment_id:
status = 'merged'
else:
status = 'pending'
rec.x_fc_thickness_qc_id = qc or empty_qc
rec.x_fc_thickness_pdf_id = pdf or empty_att
rec.x_fc_thickness_status = status
def action_view_thickness_qc(self):
"""Smart-button target — open the linked QC for inspection."""
self.ensure_one()
if not self.x_fc_thickness_qc_id:
return False
return {
'type': 'ir.actions.act_window',
'name': self.x_fc_thickness_qc_id.name,
'res_model': 'fusion.plating.quality.check',
'res_id': self.x_fc_thickness_qc_id.id,
'view_mode': 'form',
'target': 'current',
}
def action_open_job(self):
"""Smart-button target — open the linked plating job."""
self.ensure_one()
if not self.x_fc_job_id:
return False
return {
'type': 'ir.actions.act_window',
'name': self.x_fc_job_id.name,
'res_model': 'fp.job',
'res_id': self.x_fc_job_id.id,
'view_mode': 'form',
'target': 'current',
}
# ---- Parse-on-upload for the cert-form Fischerscope field (2026-05-28)
# The Issue Certs wizard parses .doc/.docx/RTF Fischerscope exports into
# readings + metadata + microscope image. Dropping the same file straight
# onto the cert form's x_fc_local_thickness_pdf field did nothing — it
# just stored the bytes. These hooks give the form the SAME behaviour as
# the wizard: on save, a non-PDF upload is parsed and relocated to the
# evidence field (a real PDF is left in place to merge as page 2).
@api.model_create_multi
def create(self, vals_list):
recs = super().create(vals_list)
for rec in recs:
if (rec.x_fc_local_thickness_pdf
and not self.env.context.get('fp_skip_thickness_parse')):
rec._fp_parse_local_thickness_upload()
return recs
def write(self, vals):
res = super().write(vals)
if (vals.get('x_fc_local_thickness_pdf')
and not self.env.context.get('fp_skip_thickness_parse')):
for rec in self:
rec._fp_parse_local_thickness_upload()
return res
def _fp_parse_local_thickness_upload(self):
"""Parse a Fischerscope .doc/.docx/RTF dropped on the cert form's
x_fc_local_thickness_pdf field, exactly like the Issue Certs wizard:
extract readings → thickness_reading_ids, header metadata →
x_fc_thickness_* fields, microscope image → x_fc_thickness_image_id,
then relocate the non-PDF source to x_fc_local_thickness_evidence_id
and clear the PDF field (so the page-2 merge doesn't choke on it).
A real PDF is left in place — it merges as page 2 of the CoC on
Issue and carries no parseable readings. Unknown non-PDF types are
left untouched.
"""
import base64
from datetime import datetime
self.ensure_one()
if not self.x_fc_local_thickness_pdf:
return
try:
raw = base64.b64decode(self.x_fc_local_thickness_pdf)
except Exception:
return
# Real PDF → leave it (merges as page 2). XDAL 600 names RTF files
# ".doc"; detect by magic bytes, not extension (see CLAUDE.md).
if raw[:4] == b'%PDF':
return
name = (self.x_fc_local_thickness_pdf_filename or '').lower()
is_rtf = raw[:5] == b'{\\rtf'
is_docx = name.endswith('.docx')
if not (is_rtf or is_docx):
return # unknown non-PDF — don't guess
from ..wizards.fp_cert_issue_wizard import (
_fp_parse_fischerscope_rtf, _fp_parse_fischerscope_docx,
_fp_extract_rtf_images, _fp_pick_microscope_image,
)
parsed = (_fp_parse_fischerscope_rtf(raw) if is_rtf
else _fp_parse_fischerscope_docx(raw))
vals = {}
for fname, fval in (
('x_fc_thickness_operator', parsed.get('operator')),
('x_fc_thickness_product', parsed.get('product')),
('x_fc_thickness_directory', parsed.get('directory')),
('x_fc_thickness_application', parsed.get('application')),
('x_fc_thickness_measuring_time_sec',
parsed.get('measuring_time_sec') or 0),
('x_fc_thickness_equipment',
parsed.get('equipment') or 'Fischerscope XDAL 600'),
('x_fc_thickness_source_filename',
self.x_fc_local_thickness_pdf_filename or ''),
):
if fname in self._fields and fval:
vals[fname] = fval
date_str = (parsed.get('date_str') or '').strip()
time_str = (parsed.get('time_str') or '').strip()
if date_str and 'x_fc_thickness_datetime' in self._fields:
combined = ('%s %s' % (date_str, time_str)).strip()
for fmt in (
'%m/%d/%Y %I:%M:%S %p', '%m/%d/%Y %I:%M %p',
'%m/%d/%Y %H:%M:%S', '%m/%d/%Y %H:%M', '%m/%d/%Y',
):
try:
vals['x_fc_thickness_datetime'] = datetime.strptime(
combined, fmt,
)
break
except ValueError:
continue
# Readings — replace any existing set with the freshly-parsed rows
# (the uploaded report is authoritative for this cert).
readings = parsed.get('readings') or []
Reading = self.env.get('fp.thickness.reading')
if readings and Reading is not None:
calibration = parsed.get('calibration') or ''
cmds = [(5, 0, 0)]
for i, (nip, ni, p) in enumerate(readings):
rvals = {'nip_mils': nip, 'ni_percent': ni, 'p_percent': p}
if 'reading_number' in Reading._fields:
rvals['reading_number'] = i + 1
if calibration and 'calibration_std_ref' in Reading._fields:
rvals['calibration_std_ref'] = calibration
cmds.append((0, 0, rvals))
vals['thickness_reading_ids'] = cmds
# Relocate the non-PDF source to the evidence slot + clear the PDF
# field (mirrors the wizard's non-PDF end state).
att = self.env['ir.attachment'].sudo().create({
'name': self.x_fc_local_thickness_pdf_filename or 'fischerscope-report',
'type': 'binary',
'datas': self.x_fc_local_thickness_pdf,
'res_model': self._name,
'res_id': self.id,
})
if 'x_fc_local_thickness_evidence_id' in self._fields:
vals['x_fc_local_thickness_evidence_id'] = att.id
vals['x_fc_local_thickness_pdf'] = False
vals['x_fc_local_thickness_pdf_filename'] = False
# Microscope image (RTF only — .docx images need a different path).
if is_rtf and 'x_fc_thickness_image_id' in self._fields:
try:
pngs = _fp_extract_rtf_images(raw)
img_bytes, img_w, img_h = _fp_pick_microscope_image(pngs)
if img_bytes:
img_att = self.env['ir.attachment'].sudo().create({
'name': '%s-microscope.png' % (
(self.x_fc_local_thickness_pdf_filename
or 'fischerscope').rsplit('.', 1)[0]
),
'type': 'binary',
'datas': base64.b64encode(img_bytes),
'mimetype': 'image/png',
'res_model': self._name,
'res_id': self.id,
})
vals['x_fc_thickness_image_id'] = img_att.id
except Exception:
pass
self.with_context(fp_skip_thickness_parse=True).write(vals)
from markupsafe import Markup
from odoo import _
self.message_post(body=Markup(_(
'Fischerscope file <b>%s</b> parsed from the cert form: '
'%d reading(s) extracted.'
)) % (
self.x_fc_thickness_source_filename or name or 'unnamed',
len(readings),
))