Replace em-dashes and en-dashes with hyphens across 789 shipped source files (py/xml/js/scss) so the delivered module reads as human-written; em-dashes had become a recognizable AI-generated tell. Internal .md dev notes are excluded. The WO-sticker mojibake strippers keep their dash search targets (now written — / –). No logic changes: comments and display strings only; validated with py_compile + lxml parse. Rewrite the 7 customer notification emails to be intake-neutral (ship-in / drop-off / pickup) and repair-aware, and fix the Shipped email documents line (packing slip vs bill of lading; certificate only when issued). Subjects use a hyphen separator. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
76 lines
2.8 KiB
Python
76 lines
2.8 KiB
Python
# -*- coding: utf-8 -*-
|
|
# Copyright 2026 Nexa Systems Inc.
|
|
# License OPL-1 (Odoo Proprietary License v1.0)
|
|
# Part of the Fusion Plating product family.
|
|
|
|
{
|
|
'name': 'Fusion Plating - Chrome Plating Process Pack',
|
|
'version': '19.0.1.0.0',
|
|
'category': 'Manufacturing/Plating',
|
|
'summary': 'Chrome plating process types - hard and decorative, hexavalent and trivalent - with bath parameter schemas and carcinogen hazard awareness.',
|
|
'description': """
|
|
Fusion Plating - Chrome Plating Process Pack
|
|
==============================================
|
|
|
|
Part of the Fusion Plating product family by Nexa Systems Inc.
|
|
|
|
This data-only module plugs into the ``fusion_plating`` core and seeds the
|
|
process taxonomy and bath chemistry schemas specific to chrome (chromium)
|
|
plating. No new models, no new views - just records loaded with
|
|
``noupdate="1"`` so downstream customizations survive upgrades.
|
|
|
|
Process types shipped
|
|
---------------------
|
|
* Hard Chrome - Hexavalent (Cr(VI))
|
|
* Decorative Chrome - Hexavalent (Cr(VI))
|
|
* Hard Chrome - Trivalent (Cr(III))
|
|
* Decorative Chrome - Trivalent (Cr(III))
|
|
* Chrome Strike
|
|
|
|
Bath parameters shipped
|
|
-----------------------
|
|
Hexavalent chromium (CrO3), trivalent chromium, sulfuric acid, CrO3:H2SO4
|
|
ratio, bath temperature, current density, iron and copper contamination,
|
|
mist suppressant level, and rectifier voltage. Per-bath target overrides
|
|
happen on the bath or recipe record in the core.
|
|
|
|
Hazard awareness
|
|
----------------
|
|
Hexavalent chrome is a confirmed human carcinogen (IARC Group 1, NTP
|
|
Known Human Carcinogen, Ontario Reg. 833 designated substance). Every
|
|
hex-chrome process type carries ``hazard_notes`` that flag:
|
|
|
|
* Ontario Reg. 833 ceiling exposure limit 0.05 mg/m³ as Cr(VI).
|
|
* Mandatory mist suppression and medical surveillance.
|
|
* Toronto Ch. 681 sewer limits - Cr(VI) 2 mg/L, total Cr 4 mg/L.
|
|
* NPRI Part 1B reporting, CEPA Schedule 1 listing.
|
|
* Mandatory rinse-water segregation - no storm sewer discharge
|
|
(storm limit 0.0008 mg/L Cr(VI)).
|
|
* Industry transition to trivalent chrome where part specs allow.
|
|
|
|
Trivalent (Cr(III)) variants are flagged as the preferred choice for new
|
|
installations, with reduced toxicity and lower fume generation - but
|
|
still subject to Toronto total-chromium discharge limits.
|
|
|
|
Install this module after ``fusion_plating``. It depends only on the core
|
|
module and ships no security rules or views of its own.
|
|
|
|
Copyright (c) 2026 Nexa Systems Inc. All rights reserved.
|
|
""",
|
|
'author': 'Nexa Systems Inc.',
|
|
'website': 'https://www.nexasystems.ca',
|
|
'maintainer': 'Nexa Systems Inc.',
|
|
'support': 'support@nexasystems.ca',
|
|
'license': 'OPL-1',
|
|
'price': 0.00,
|
|
'currency': 'CAD',
|
|
'depends': ['fusion_plating'],
|
|
'data': [
|
|
'data/fp_bath_parameter_data.xml',
|
|
'data/fp_process_type_data.xml',
|
|
],
|
|
'installable': True,
|
|
'application': False,
|
|
'auto_install': False,
|
|
}
|