feat(iot): Sub 7 — per-sensor polling interval + rate-limit + entech seed

Per-sensor override on fp.tank.sensor.poll_interval_minutes with a
company-wide default (res.company.x_fc_default_poll_interval_minutes,
default 30) exposed in Settings → Fusion Plating → IoT. Single
lookup helper _fp_effective_poll_interval_minutes keeps downstream
call sites simple. Read-only poll_interval_display Char ("30 min
(default)" / "15 min (override)") keeps units unambiguous per user
request.

Ingest endpoint /fp/iot/ingest drops readings that arrive inside a
sensor's effective interval, returning {accepted, skipped} so the Pi
agent can log it. Pi-side interval stays its own concern.

Post-init hook seeds 5 small tanks + 20 big tanks (10 active, 10
inactive) with 1 temperature + 1 pH sensor each → 25 tanks, 50
sensors. Idempotent (keyed by tank.code, with_context(active_test=
False)). Opt-in via ir.config_parameter
fusion_plating_iot.seed_entech_tanks = '1' so a fresh install
elsewhere doesn't auto-seed. Flag set on entech today; 27 tanks / 52
sensors now live (2 pilot + 25 seeded).

Smoke on entech: 14/14 assertions pass including idempotency and
rate-limit conditions.

fusion_plating_iot → 19.0.2.0.0

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
gsinghpal
2026-04-22 23:29:08 -04:00
parent def9c801fa
commit a7fd39d6f3
11 changed files with 358 additions and 5 deletions

View File

@@ -372,7 +372,7 @@ rewrite code as new requirements surface. Each sub-project has its own design do
| 4 | Contract Review (optional, per-part, settings-driven QA roster, QA-005 1:1 PDF) | **Shipped 2026-04-22** | 2i |
| 5 | Order-line fields (fp.serial registry, auto job#, coating-scoped thickness dropdown, revision picker) | **Shipped 2026-04-22** | 5, 6, Q2 |
| 6 | Contact Profiles & Communication Routing (sub-contacts + per-location notification lists + global contacts) | Pending | client transcript A/B/C |
| 7 | IoT tuning (configurable polling interval 1530 min, seed 610 tank sensors) | Pending | client transcript D |
| 7 | IoT tuning (per-sensor polling interval + ingest rate-limit; entech seeded with 25 tanks / 50 sensors) | **Shipped 2026-04-22** | client transcript D |
| 8 | Receiving / Inspection / QC flow restructure (split receiving vs inspection; racking crew inspects, not receiver) | Pending | client transcript E |
| ∞ | First-off / last-off QC | Deferred | client transcript F |
| ∞ | VEC machine auto-ingest (Word-format thickness report from network-connected XRF; different machine from Fischerscope) | Deferred | client transcript G |