# Fusion Plating — Nuclear (CSA N299, NQA-1)
Part of the Fusion Plating product family by Nexa Systems Inc.
Nuclear industry pack for plating and metal finishing shops that supply
the Canadian and US nuclear sectors. Layers on top of
`fusion_plating_quality`.
## What's in the box
- **CSA N299 level catalog** — Levels 1 through 4, safety classification,
default records retention (40 / 25 / 15 / 7 years).
- **Nuclear Quality Programs** — per facility, with N299 level, NQA-1
applicability, CNSC supplier status and audit dates.
- **Inspection and Test Plans (ITP)** — hold points, witness points, test
methods, acceptance criteria, customer review workflow.
- **10 CFR Part 21 reports** — 60-day evaluation clock, reportability
determination, customer notification and closure.
- **Nuclear Pedigree Records** — full traceability from raw material heat
number through chemistry, process steps, test results, ship date, and
computed retention-until date.
- **CNSC Licence tracking** — Class II nuclear facility, transport and
export licences with expiry monitoring.
- **Customer spec extension** — nuclear flag, N299 level, NQA-1 flag,
nuclear customer type (OPG, Bruce Power, AECL, Cameco, Candu Energy,
US utility).
- **NCR extension** — nuclear flag and 10 CFR Part 21 evaluation hook.
- **res.company extension** — default nuclear records retention.
## Background
- **CSA N299** — Canadian quality assurance program requirements for
items and services supplied to nuclear power plants. Four levels:
Level 1 (safety-critical) through Level 4 (commercial grade).
- **NQA-1** — US nuclear quality assurance for US facilities.
- **CNSC** — Canadian Nuclear Safety Commission, federal regulator.
- **10 CFR Part 21** — US regulation requiring reporting of defects and
noncompliance that could create a substantial safety hazard.
- **ITP** — Inspection and Test Plan.
- **Nuclear pedigree** — full traceability from raw material to
installed component.
## Canadian nuclear customers (seeded templates)
- **OPG** — Ontario Power Generation (Pickering, Darlington)
- **Bruce Power** — Bruce A and Bruce B
- **AECL / CNL** — Atomic Energy of Canada / Canadian Nuclear
Laboratories (Chalk River)
- **Candu Energy** — SNC-Lavalin Candu Energy (Candu reactor OEM)
## Dependencies
- `fusion_plating_quality`
## Install
1. Drop the module into your Odoo addons path.
2. Update the apps list.
3. Install **Fusion Plating — Nuclear**.
4. Go to **Plating → Nuclear** to start configuring programs and ITPs.
## License
OPL-1 (Odoo Proprietary License v1.0). Copyright 2026 Nexa Systems Inc.