Per-sensor override on fp.tank.sensor.poll_interval_minutes with a
company-wide default (res.company.x_fc_default_poll_interval_minutes,
default 30) exposed in Settings → Fusion Plating → IoT. Single
lookup helper _fp_effective_poll_interval_minutes keeps downstream
call sites simple. Read-only poll_interval_display Char ("30 min
(default)" / "15 min (override)") keeps units unambiguous per user
request.
Ingest endpoint /fp/iot/ingest drops readings that arrive inside a
sensor's effective interval, returning {accepted, skipped} so the Pi
agent can log it. Pi-side interval stays its own concern.
Post-init hook seeds 5 small tanks + 20 big tanks (10 active, 10
inactive) with 1 temperature + 1 pH sensor each → 25 tanks, 50
sensors. Idempotent (keyed by tank.code, with_context(active_test=
False)). Opt-in via ir.config_parameter
fusion_plating_iot.seed_entech_tanks = '1' so a fresh install
elsewhere doesn't auto-seed. Flag set on entech today; 27 tanks / 52
sensors now live (2 pilot + 25 seeded).
Smoke on entech: 14/14 assertions pass including idempotency and
rate-limit conditions.
fusion_plating_iot → 19.0.2.0.0
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
62 lines
2.1 KiB
Python
62 lines
2.1 KiB
Python
# -*- coding: utf-8 -*-
|
|
# Copyright 2026 Nexa Systems Inc.
|
|
# License OPL-1 (Odoo Proprietary License v1.0)
|
|
# Part of the Fusion Plating product family.
|
|
|
|
{
|
|
'name': 'Fusion Plating — IoT Integration',
|
|
'version': '19.0.2.0.0',
|
|
'category': 'Manufacturing/Plating',
|
|
'summary': 'Wire physical tank sensors to Fusion Plating — live '
|
|
'temperature / chemistry readings with auto quality holds '
|
|
'on out-of-spec.',
|
|
'description': """
|
|
Fusion Plating — IoT Integration
|
|
================================
|
|
|
|
Bridges the generic `iot` module (IoT Box + device management) to
|
|
plating-specific models:
|
|
|
|
* ``fp.tank.sensor`` — maps an ``iot.device`` to a
|
|
``fusion.plating.tank`` (or a ``fusion.plating.bath``).
|
|
* ``fp.tank.reading`` — time-series log of every sensor reading.
|
|
* Auto-creates a ``fusion.plating.quality.hold`` when a reading
|
|
falls outside the tank/bath's target range (per
|
|
``fusion.plating.bath.parameter`` spec).
|
|
|
|
Supports both the Odoo-IoT proxy path (Pi running iot_drivers) AND
|
|
a direct HTTP ingest path (``/fp/iot/ingest``) for sensors that
|
|
skip the proxy and POST straight to Odoo with a shared secret.
|
|
|
|
Part of the Fusion Plating product family by Nexa Systems Inc.
|
|
""",
|
|
'author': 'Nexa Systems Inc.',
|
|
'website': 'https://www.nexasystems.ca',
|
|
'maintainer': 'Nexa Systems Inc.',
|
|
'support': 'support@nexasystems.ca',
|
|
'license': 'OPL-1',
|
|
'price': 0.00,
|
|
'currency': 'CAD',
|
|
'depends': [
|
|
'iot',
|
|
'fusion_plating',
|
|
'fusion_plating_quality',
|
|
],
|
|
'data': [
|
|
'security/ir.model.access.csv',
|
|
'data/ir_config_parameter_data.xml',
|
|
'data/fp_sensor_type_data.xml',
|
|
'views/fp_sensor_type_views.xml',
|
|
'views/fp_sensor_dashboard_views.xml',
|
|
'views/fp_tank_sensor_views.xml',
|
|
'views/fp_tank_reading_views.xml',
|
|
'views/fusion_plating_tank_views.xml',
|
|
'views/res_config_settings_views.xml',
|
|
'views/fp_iot_menu.xml',
|
|
],
|
|
'post_init_hook': 'post_init_hook',
|
|
'installable': True,
|
|
'application': False,
|
|